Skip to main content
Siemens 3VA1110-5ED32-0BH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-5ED32-0BH0 SENTRON MCCB, 100 A, 3-Pole, TM21

MPN3VA1110-5ED32-0BH0

Siemens SENTRON 3VA1110-5ED32-0BH0, molded case circuit breaker, 3-pole, 100 A, TM210 thermal-magnetic release, line protection, 70 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-5ED32-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1110-5ED32-0BH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96 A
Current at 60 °C94 A
Current at 65 °C92 A
Current at 70 °C90 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 690 V17 kA
3VA1110-5ED32-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1110-5ED32-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-5ED32-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1110-5ED32-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-5ED32-0BH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The interrupting ratings climb with voltage: 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V. That spread tells you the breaker is built for high-fault installations — the 121 kA at 415 V covers most European industrial distribution, while the 75.6 kA at 440 V handles North American 480 V panels with headroom. What you set at the factory is what you get. That keeps the part simple for panel builders who want a known coordination curve without field-adjustment risk.

The breaker holds its full 100 A rating from 40 °C through 50 °C, then begins to derate: 96 A at 55 °C, 94 A at 60 °C, 92 A at 65 °C, and 90 A at 70 °C. No washdown rating; keep this behind a gland plate or enclosure door in wet environments.

The auxiliary contact block is factory-installed; the order code for the integrated auxiliary trip module is 3VA9608-0BB11 if you need a spare or replacement.

For compliance documentation: the SENTRON 3VA series carries UL 489, CSA C22.2 No. 5, and IEC 60947-2 certifications. RoHS and REACH declarations are available through Siemens Industry Online Support.

The 76.2 mm width is a standard 3-pole MCCB footprint — three 25.4 mm pole centers — so it fits existing bus-bar and lug layouts without re-drilling. Depth of 70 mm leaves clearance for rear-connected bus stabs or plug-in bases in switchgear.

Frequently asked questions

What is 3VA1110-5ED32-0BH0's listed depth?

The depth is 70 mm. That measurement is from the mounting surface to the front face of the breaker — important for enclosure depth clearance when using rear-connected bus bars or plug-in bases.

MPN
3VA1110-5ED32-0BH0