Skip to main content
Siemens 3VA1110-5ED32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-5ED32-0DH0 SENTRON MCCB, 100A 3-Pole, 187kA

MPN3VA1110-5ED32-0DH0

Siemens SENTRON 3VA1110-5ED32-0DH0, 3-pole molded case circuit breaker, 100 A at 40 °C, interrupting 187 kA at 240 V, with undervoltage release and auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-5ED32-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11105ED320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1110-5ED32-0DH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.27.5 W
3VA1110-5ED32-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1110-5ED32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-5ED32-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1110-5ED32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-5ED32-0DH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What this 100 A MCCB brings to the panel

The Siemens SENTRON 3VA1110-5ED32-0DH0 is a 3-pole molded case circuit breaker rated 100 A continuous at 40 °C — the same rating holds at 45 °C and 50 °C, then gently derates to 91 A at 70 °C. That uninterrupted 100 A band through the first 10 °C above standard ambient buys you thermal headroom in a warm enclosure without upsizing the frame. Interrupting capacity hits 187 kA at 240 V, 121 kA at 415 V, and 75.6 kA at 440 V — numbers that put this squarely in the high-fault category for industrial mains distribution. At 690 V it still clears 17 kA, so it handles the full IEC utilization range without a current-limiting assist. Line protection design means it's configured for feeder duty out of the box, not motor branch protection.

Footprint and integration

Width is 76.2 mm (3 in), height 130 mm, depth 70 mm. Fits a standard DIN-rail or panel-mount footprint. Maximum power loss is 27.5 W per pole.

MPN