Siemens 3VA1110-5ED32-0JA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-5ED32-0JA0 SENTRON MCCB, 100 A, 187 kA at 24

MPN3VA1110-5ED32-0JA0

Siemens SENTRON 3VA1110-5ED32-0JA0, molded case circuit breaker, 3-pole, 100 A rated continuous current, interrupting rating 187 kA at 240 V AC, line protection version with TM210 release and shunt trip.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-5ED32-0JA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1110-5ED32-0JA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96 A
Current at 60 °C94 A
Current at 65 °C92 A
Current at 70 °C90 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 690 V17 kA
3VA1110-5ED32-0JA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1110-5ED32-0JA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-5ED32-0JA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1110-5ED32-0JA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-5ED32-0JA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1110-5ED32-0JA0 is a 3-pole molded case circuit breaker rated for 100 A continuous current (Iu) at 40 °C through 50 °C, derating to 90 A at 70 °C. Its interrupting capacity hits 187 kA at 240 V AC and 121 kA at 415 V AC, which puts it in the high-fault tier for industrial distribution panels where the available short-circuit current is well above typical 25–65 kA ranges.

Interrupting rating — why 187 kA matters

At 240 V, this breaker clears 187 kA without failing — that is the SCCR at the line side, not a coordination number. For a panel fed by a transformer with low impedance, or one close to the utility service entrance, the available fault current can exceed 100 kA easily. A standard 65 kA MCCB would not hold; this one does. At 415 V it still clears 121 kA, and at 690 V it drops to 17 kA, which is still adequate for most 690 V motor circuits.

No auxiliary contacts are built in; if you need status feedback to a PLC, you add the optional auxiliary switch block later.

What the TM210 release and shunt trip mean for your BOM

The overcurrent release is a TM210 — a thermal-magnetic type with fixed thermal pickup and magnetic short-circuit pickup. It is not adjustable, so the breaker is factory-set for a 100 A frame. The shunt trip (STL) is built in, allowing remote tripping via a control voltage. The integrated auxiliary trip is order code 3VA9688-0BL32, which is the shunt trip coil itself.

Temperature derating — the real continuous current

Above that, it derates: 96 A at 55 °C, 94 A at 60 °C, 92 A at 65 °C, and 90 A at 70 °C. If your panel ambient runs at 60 °C, plan for 94 A continuous — not the nameplate 100 A.

Frequently asked questions

What is the closest functional second-source — 3VA1110-5EE32-0JA0?

The 3VA1110-5EE32-0JA0 is the closest sibling in the same 3VA platform. Both are 3-pole, 100 A MCCBs with TM210 releases. The difference is in the interrupting rating: the -5ED32 variant carries 187 kA at 240 V, while the -5EE32 variant typically carries a lower interrupting rating (check the specific variant specs). The physical footprint (130 x 76.2 x 70 mm) is identical, so it drops into the same panel cutout and busbar arrangement without rewiring.

Where can I buy 3VA1110-5ED32-0JA0?

This part is sourced and quoted to order against an RFQ through our independent distribution network. Availability and current pricing are confirmed at quote time — send an RFQ and we will respond with a firm offer.

What compliance documentation does Siemens provide for this MCCB?

Siemens provides RoHS, REACH, UL, and IEC compliance documentation for the SENTRON 3VA series. The breaker carries a reference code Q per DIN EN 81346-2 and is designed for line protection per IEC 60947-2.

Will 3VA1110-5ED32-0JA0 drop into a panel specified around 3VA1110-5EE32-0JA0?

Yes. Both variants share the same 130 mm height, 76.2 mm width, and 70 mm depth, so the physical fit is identical. The busbar connections and DIN-rail mounting are the same. No rewiring is needed for the panel cutout.