Siemens 3VA1110-5ED42-0AA0-ZD00 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-5ED42-0AA0-ZD00 Circuit Breaker, 55kA @ 415V

MPN3VA1110-5ED42-0AA0-ZD00

Siemens 3VA1 IEC frame 160 MCCB, breaking capacity class M, Icu=55kA @ 415V, 4-pole, line protection TM210, In=100A, Ir=100A fixed, Ii=10 x In.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

Integrator note

The Siemens 3VA1110-5ED42-0AA0-ZD00 is a 4-pole IEC frame 160 molded-case circuit breaker with a 55 kA interrupting capacity at 415 V (class M). The TM210 trip unit gives fixed thermal-magnetic overload protection at 100 A (Ir = 100 A) and a short-circuit pickup fixed at 10× In, so it holds steady under motor inrush but clears a bolted fault fast. The N conductor is unprotected — confirm the neutral is not expected to carry fault current in your distribution scheme.

What the ratings mean for fit

The 55 kA Icu at 415 V is the maximum short-circuit current the breaker can safely interrupt once — class M (medium breaking capacity) covers most industrial panel secondary distribution where fault levels stay under 55 kA. The fixed Ir = 100 A means no thermal adjustment dial; the breaker is sized for a 100 A continuous load. The Ii = 10 × In (1000 A) short-circuit pickup is a fixed magnetic setting — suitable for feeder circuits where the inrush is moderate; for high-inrush transformer or motor loads a higher Ii or electronic trip unit would be needed.

Frequently asked questions

Where can I buy 3VA1110-5ED42-0AA0-ZD00 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What does the TM210 trip unit mean on this breaker?

TM210 is a fixed thermal-magnetic trip: the thermal overload is fixed at Ir = 100 A (no adjustment), and the magnetic short-circuit pickup is fixed at Ii = 10 × In (1000 A). It is a simple, non-adjustable feeder protection device.

What compliance documentation does Siemens provide for 3VA1110-5ED42-0AA0-ZD00?

The evidence does not list specific compliance documentation for this order code. Standard Siemens 3VA series breakers typically carry IEC 60947-2 certification and RoHS/REACH declarations; confirm the exact documentation package with your Siemens contact or distributor at quote time.