Skip to main content
Siemens 3VA1110-5EF32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-5EF32-0DA0 SENTRON MCCB, 100 A, 187 kA at 24

MPN3VA1110-5EF32-0DA0

Siemens SENTRON 3VA1110-5EF32-0DA0, molded case circuit breaker, 3-pole, 100 A, 187 kA at 240 V, line protection, TM240 release, undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-5EF32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1110-5EF32-0DA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96 A
Current at 60 °C94 A
Current at 65 °C92 A
Current at 70 °C90 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 690 V17 kA
3VA1110-5EF32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1110-5EF32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-5EF32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1110-5EF32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-5EF32-0DA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

What this 3VA1110-5EF32-0DA0 brings to a panel

The Siemens 3VA1110-5EF32-0DA0 is a 3-pole SENTRON molded case circuit breaker (MCCB) rated for 100 A continuous current at 40 °C — the same rating holds through 50 °C, then derates to 90 A at 70 °C.

Sizing and thermal derating for cold-chain or warm environments

At 55 °C it drops to 96 A, at 60 °C to 94 A, at 65 °C to 92 A, and at 70 °C to 90 A. For a cold-storage freezer panel operating near -25 °C (the minimum operating temperature), the breaker runs cold and stays cold — no thermal trip nuisance from ambient cold.

The 70 mm depth leaves clearance for rear busbar connections in a typical 200 mm deep enclosure.

Frequently asked questions

Where can I buy the 3VA1110-5EF32-0DA0 and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time figure is published here.

What are the key ratings of the 3VA1110-5EF32-0DA0?

3-pole molded case circuit breaker rated 100 A continuous at 40 °C, with breaking capacities of 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V. It uses a TM240 thermal-magnetic release and includes an undervoltage release.

Will the 3VA1110-5EF32-0DA0 drop into a panel specified for the 3VA1110-5EE32-0JA0?

Both are 3-pole SENTRON 3VA frame breakers with the same 76.2 mm width, 130 mm height, and 70 mm depth — the panel cutout and busbar spacing are identical. The difference is the release: the 5EF32-0DA0 carries a TM240 release and an undervoltage release, while the 5EE32-0JA0 uses a different release variant. Check the release curve and auxiliary requirements before swapping.

What compliance documentation does Siemens provide for this MCCB?

The breaker carries a DIN EN 81346-2 reference code Q and is designed to IEC/EN 60947-2 standards for molded case circuit breakers. Siemens typically provides RoHS and REACH declarations, plus UL/CSA certifications for the SENTRON 3VA family — consult the product documentation for the specific certificate numbers.

MPN
3VA1110-5EF32-0DA0