Skip to main content
Siemens 3VA1110-5EF32-0HA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-5EF32-0HA0 SENTRON MCCB, 100 A, 3-Pole, TM24

MPN3VA1110-5EF32-0HA0

Siemens SENTRON 3VA1110-5EF32-0HA0, molded case circuit breaker, 3-pole, 100 A rated continuous current, TM240 thermal-magnetic overcurrent release, line protection version, 70 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-5EF32-0HA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1110-5EF32-0HA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96 A
Current at 60 °C94 A
Current at 65 °C92 A
Current at 70 °C90 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 690 V17 kA
3VA1110-5EF32-0HA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1110-5EF32-0HA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-5EF32-0HA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1110-5EF32-0HA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-5EF32-0HA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

MCCB for line protection — 100 A, 3-pole, TM240 release

This MCCB delivers 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V. For a 415 V panel with a prospective short-circuit current of 100 kA, this breaker clears it without cascading upstream.

Above that it derates linearly: 96 A at 55 °C, 94 A at 60 °C, 92 A at 65 °C, and 90 A at 70 °C. If your enclosure ambient runs at 55 °C, plan for 96 A continuous — not 100 A. The 15 000 latching endurance cycles give a service life estimate for switching applications.

The breaker measures 130 mm high, 76.2 mm wide, and 70 mm deep — a compact footprint for a 100 A MCCB. The IP40 front protection means it is sealed against tools and solid objects larger than 1 mm on the front face, but not against dust ingress or water; mount it inside a panel with a higher overall rating. The reference code Q per DIN EN 81346-2 is used for circuit-breaker identification in schematics. For DC network applications, consult the 3VA device manual referenced in the datasheet.

Frequently asked questions

What overcurrent release does this breaker use?

It uses a TM240 thermal-magnetic overcurrent release, which provides both thermal (overload) and magnetic (short-circuit) protection. The 'TM' indicates a fixed thermal and fixed magnetic trip curve.

Does this breaker include an auxiliary contact or shunt trip?

It includes a shunt trip (STL) auxiliary release (order code 3VA9688-0BL30) for remote tripping, but it does not include a separate auxiliary contact block. No undervoltage release, ground-fault monitoring, or communication function is fitted.

MPN
3VA1110-5EF32-0HA0