Siemens 3VA1110-5EF42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-5EF42-0AA0 SENTRON MCCB, 100 A, 4-Pole, TM24

MPN3VA1110-5EF42-0AA0
Active

Siemens SENTRON 3VA1110-5EF42-0AA0, molded case circuit breaker, 4-pole, 100 A, TM240 thermal-magnetic release, breaking capacity 187 kA at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-5EF42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1110-5EF42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.25 W
3VA1110-5EF42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1110-5EF42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-5EF42-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1110-5EF42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-5EF42-0AA0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1110-5EF42-0AA0 is a 4-pole molded case circuit breaker (MCCB) rated 100 A continuous at 40 °C with a TM240 thermal-magnetic release. The 4-pole design covers three-phase plus neutral switching, which matters for TN-S or TN-C-S systems where the neutral must be isolated on fault clearing.

Panel fit and mounting — dimensions and integration

The 3VA1110-5EF42-0AA0 measures 130 mm high, 101.6 mm wide, and 70 mm deep. The 101.6 mm width (4 inches) is the standard 4-pole MCCB footprint in the SENTRON 3VA platform, so it occupies the same DIN-rail or screw-mount space as other 4-pole 3VA frames. Depth of 70 mm (2.76 in) leaves enough clearance for rear-connection busbars or plug-in adapters in a typical 600 mm deep enclosure. Front IP40 protection means the breaker is splash-proof from the front but not sealed; install it in a panel with an IP54 or better door if washdown is present.

Frequently asked questions

What is the closest functional second-source to 3VA1110-5EF42-0AA0?

The 3VA1110-5EF36-0AD0 is the closest peer — same 100 A frame, 4-pole, TM240 release. The difference is in the breaking capacity at specific voltages; verify the interrupting rating at your system voltage before substituting.

Will 3VA1110-5EF42-0AA0 drop into a panel specified around 3VA1110-5EF36-0AD0 without rewiring?

Yes — both are 4-pole 100 A MCCBs with the same 101.6 mm width and 130 mm height, so the mounting footprint and busbar connections are identical. The depth is also 70 mm on both. No rewiring needed for the same panel cutout.