Siemens 3VA1 IEC frame 160, 4-pole MCCB, breaking capacity class M, Icu=55kA @ 415V, TM210 line protection, In=100A, Ir=100A fixed, Ii=10 x In, N conductor protection 100%, nut keeper kit for DC Power OEM in China.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA1110-5GD42-0AA0-ZD00 is an IEC frame 160 molded case circuit breaker in the 3VA1 series, configured as a 4-pole unit with breaking capacity class M — meaning it delivers an Icu of 55 kA at 415 V AC. That rating places it in the medium-high fault-current tier for IEC distribution panels, sized for industrial main or sub-feed protection where the prospective short-circuit current sits above 25 kA but below 65 kA. The TM210 trip unit provides fixed thermal-magnetic line protection: In = 100 A, Ir = 100 A (overload), and Ii = 10 × In (short-circuit magnetic pickup at 1000 A). N-conductor protection is set at 100%, meaning the neutral pole tracks the phase poles — typical for 4-wire systems where the neutral carries full phase current.

For IEC 60947-2 installations, this class M rating covers most industrial distribution boards fed from a transformer in the 1–2 MVA range. If your available fault current exceeds 55 kA, you need a higher-class frame (class H or class L in the 3VA family). The fixed Ir = 100 A and Ii = 10 × In (1000 A) means this is not field-adjustable for load changes. If the downstream load is exactly 100 A and the cable is sized for that, it fits. If you need a different overload setting or a wider magnetic pickup range, you would look at the 3VA2 series with electronic trip units.

Deployment Context

This 4-pole MCCB mounts in a standard IEC distribution panel or switchboard via the 3VA mounting accessories. The nut keeper kit simplifies panel-builder installation for the DC Power OEM application it was configured for. No DIN-rail mounting — this is a bolted-frame breaker for fixed or withdrawable chassis.

Frequently asked questions

Who supplies 3VA1110-5GD42-0AA0-ZD00 and how is it quoted?

This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time; volume inquiries are handled per request.

What is the closest alternative to 3VA1110-5GD42-0AA0-ZD00 in the 3VA family?

A standard catalog 3VA1 4-pole 100 A TM210 without the ZD00 suffix is the closest functional match, but it may lack the nut keeper kit and the specific OEM configuration. Verify accessory compatibility before substituting.