Siemens 3VA1110-5MH32-0AD0 Circuit Breaker, 55kA @ 415V, 100

MPN3VA1110-5MH32-0AD0

Siemens 3VA1 series, IEC frame 160 MCCB, breaking capacity class M Icu=55kA @ 415V, 3-pole, starter protection TM120M, In=100A, short-circuit protection Ii=5...15 x In, nut keeper kit, 3 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA1110-5MH32-0AD0 is a 3-pole IEC frame 160 molded-case circuit breaker from the 3VA1 series, rated at 100 A with a breaking capacity of 55 kA at 415 V (class M). It comes with a TM120M thermal-magnetic release set for starter protection — meaning the thermal element is sized to track motor heating, and the magnetic trip (Ii) is adjustable from 5 to 15 times the rated current, so you dial in the short-circuit pickup to match the motor's inrush without nuisance trips.

55 kA Icu at 415 V puts this in the 'M' (medium) breaking capacity class — enough to handle most industrial distribution faults without cascading upstream. The TM120M release gives you motor protection: the thermal element handles overloads up to 100 A, and the adjustable magnetic element lets you set Ii between 500 A and 1500 A (5–15 x In) so a 100 A motor's locked-rotor current won't pop the breaker on start. No overload relay is built in — this is short-circuit + backup thermal only; the motor's primary overload protection comes from a separate relay or contactor. The nut keeper kit and three auxiliary switches (HQ) ship with the breaker, ready for panel wiring.

Frequently asked questions

What does 'starter protection TM120M' mean on this breaker?

The TM120M release combines a thermal element rated for motor overload tracking up to 100 A with an adjustable magnetic short-circuit trip (Ii = 5–15 x In). It protects the motor feeder from short circuits and provides backup thermal protection, but the primary motor overload protection must come from a separate overload relay or contactor.

Where can I buy the 3VA1110-5MH32-0AD0?

This breaker is sourced and quoted to order against an RFQ through independent distribution. Current pricing and availability are confirmed at the time of quote.

What is the breaking capacity of this MCCB?

It has an Icu of 55 kA at 415 V, placing it in breaking capacity class M (medium) on the IEC frame 160 platform.

MPN
3VA1110-5MH32-0AD0