Siemens 3VA1110-5MH36-0KH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-5MH36-0KH0 Circuit Breaker, 100A, 55kA @ 415

MPN3VA1110-5MH36-0KH0

Siemens 3VA1 series, IEC frame 160, breaking capacity class M, 3-pole, In=100A, Icu=55kA @ 415V, starter protection TM120M, AM, shunt trip (STL) 220-250 V DC; 208-277 V AC, 2 auxiliary switches HQ, 1 trip alarm switch HQ, clamp connection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

What this 3VA1 MCCB carries

The Siemens 3VA1110-5MH36-0KH0 is a 3-pole IEC frame 160 molded case circuit breaker with a 100 A continuous rating and a 55 kA interrupting capacity at 415 V AC (breaking capacity class M). It ships with a TM120M thermal-magnetic trip unit configured for starter protection (AM characteristic), adjustable short-circuit pickup Ii = 5...15 x In. The thermal element is fixed at 100 A; there is no separate overload relay in the package — this breaker provides the short-circuit protection leg for a motor starter combination, not the full overload function. The integrated shunt trip (STL) operates on 220-250 V DC or 208-277 V AC, letting a remote emergency-stop or PLC-based trip signal open the breaker without a separate contactor.

Panel and integration notes

Clamp-type line and load terminals accept copper or aluminum conductors — no lug kit needed for most panel builds. The 3VA1 frame 160 footprint is standard for Siemens IEC switchgear; it occupies the same panel cutout and bus-bar spacing as other 3VA1 breakers, so a panel layout designed for a 160 A frame accepts this 100 A unit without re-drilling. The shunt trip coil draws power only during the trip event. Verify the control supply matches the STL rating (220-250 V DC or 208-277 V AC) before wiring.

Frequently asked questions

What is the interrupting rating of this breaker?

The breaking capacity class M gives an Icu of 55 kA at 415 V AC. That is the maximum fault current the breaker can safely interrupt at that voltage without damage.

Does this breaker include overload protection for a motor?

No. The TM120M trip unit provides short-circuit protection only (adjustable Ii = 5...15 x In). A separate overload relay is required for motor overload protection.

MPN
3VA1110-5MH36-0KH0