Siemens 3VA1110-6EE36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-6EE36-0AA0 SENTRON MCCB, 100 A, 220 kA

MPN3VA1110-6EE36-0AA0
Active

Siemens SENTRON 3VA1110-6EE36-0AA0, 3-pole molded case circuit breaker, 100 A (40 °C), TM220 release, 220 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-6EE36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1110-6EE36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.25 W
3VA1110-6EE36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1110-6EE36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-6EE36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1110-6EE36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-6EE36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

SENTRON 3VA1110-6EE36-0AA0 — 100 A MCCB, TM220, 220 kA

The Siemens SENTRON 3VA1110-6EE36-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated 100 A at 40 °C, with a TM220 thermal-magnetic release. Its interrupting capacity hits 220 kA at 240 V, dropping to 154 kA at 415 V and 121 kA at 440 V — still substantial for high-fault distribution panels. At 500 V and 690 V it holds 17 kA, so it handles standard 480Y/277 V services without issue.

The 100 A rating holds from 40 °C through 50 °C without derating — that's a full 10 °C margin over the standard 40 °C reference point. At 55 °C it's 98 A, at 60 °C it's 96 A, at 65 °C it's 94 A, and at 70 °C it's 91 A. For a panel running warm near the top of a switchboard, you lose less than 10 % capacity even at 70 °C ambient. At 415 V it's 154 kA, so it's still comfortable on high-fault 400 V distribution boards.

Dimensions are 130 mm high, 76.2 mm wide, 70 mm deep — a standard 3-pole MCCB footprint that drops into SENTRON mounting bases or DIN-rail adapters. Maximum power loss is 25 W — that's the heat it dumps into the enclosure. In a densely packed panel, that matters for thermal management. No trip indicator, no undervoltage release coil to wire.

No obsolescence notice, no last-time-buy window. It's a standard SENTRON 3VA line-protection MCCB, widely specified for commercial and industrial distribution.

Frequently asked questions

What does the TM220 release mean on this MCCB?

TM220 is a thermal-magnetic release: the thermal (overload) element is fixed, the magnetic (short-circuit) pickup is adjustable. It is designed for line/feeder protection, not motor protection.

MPN