Skip to main content
Siemens 3VA1110-6EF32-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-6EF32-0AB0 SENTRON MCCB, 100 A, 220 kA at 24

MPN3VA1110-6EF32-0AB0

Siemens SENTRON 3VA1110-6EF32-0AB0, molded case circuit breaker, 3-pole, 100 A, TM240 overcurrent release, breaking capacity 220 kA at 240 V, 154 kA at 415 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-6EF32-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA11
3VA1110-6EF32-0AB0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96 A
Current at 60 °C94 A
Current at 65 °C92 A
Current at 70 °C90 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 690 V17 kA
3VA1110-6EF32-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1110-6EF32-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-6EF32-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1110-6EF32-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-6EF32-0AB0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

SENTRON 3VA1110-6EF32-0AB0 — 100 A MCCB with TM240 release

That keeps the part simple and reliable for line-protection duty where adjustable long-time, short-time, or ground-fault curves aren't required. The 3-pole construction covers three-phase loads up to 100 A. Current rating holds flat at 100 A from 40 °C through 50 °C ambient (–), then derates to 96 A at 55 °C, 94 A at 60 °C, 92 A at 65 °C, and 90 A at 70 °C (–). For a panel running at 55 °C ambient, you lose 4 A of headroom — factor that into the load calculation if the breaker is near its limit.

Comes with 2 auxiliary switches HP factory-installed — no need to order and fit them separately.

For selectivity (discrimination) studies, the TM240 release's fixed magnetic pickup is around 10× In (1000 A typical for thermal-magnetic), so upstream devices need a short-time delay or higher instantaneous threshold to avoid nuisance tripping on motor-start inrush. Siemens publishes selectivity tables for the 3VA range — use those for coordination studies rather than relying on rule-of-thumb.

MPN
3VA1110-6EF32-0AB0