Skip to main content
Siemens 3VA1110-6EF32-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-6EF32-0AD0 SENTRON MCCB, 100 A, 3-Pole, 220

MPN3VA1110-6EF32-0AD0

Siemens SENTRON 3VA1110-6EF32-0AD0, molded case circuit breaker, 3-pole, 100 A, breaking capacity 220 kA at 240 V, 154 kA at 415 V, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-6EF32-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11106EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1110-6EF32-0AD0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.25 W
3VA1110-6EF32-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1110-6EF32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-6EF32-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1110-6EF32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-6EF32-0AD0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

That 100 A holds flat from 40 °C to 50 °C before the thermal-magnetic trip (TM240 release) starts its derating curve — at 65 °C it still carries 94 A, which means this breaker handles a warm panel without forced cooling. Breaking capacity is the headline: 220 kA at 240 V, 154 kA at 415 V, and still 17 kA at 690 V, so it clears high-fault scenarios downstream of a large transformer without needing a current-limiting upstream device.

Footprint is 76.2 mm wide, 130 mm tall, 70 mm deep — standard for a 3-pole 100 A frame in the 3VA platform.

Frequently asked questions

What is the breaking capacity of 3VA1110-6EF32-0AD0 at different voltages?

Rated breaking capacity is 220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, and 17 kA at both 500 V and 690 V. These figures apply across the three poles.

Where can I buy 3VA1110-6EF32-0AD0 and how is it quoted?

This MCCB is sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

Does 3VA1110-6EF32-0AD0 include an undervoltage release or communication module?

No. This variant has no undervoltage release, no communication function, and no ground-fault monitoring. It is a straight line-protection breaker with a TM240 thermal-magnetic trip unit.

MPN
3VA1110-6EF32-0AD0