Siemens 3VA1110-6EF32-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-6EF32-0HC0 SENTRON MCCB, 100 A, 3-Pole, 220

MPN3VA1110-6EF32-0HC0

Siemens SENTRON 3VA1110-6EF32-0HC0, molded case circuit breaker, 3-pole, 100 A rated current, 220 kA breaking capacity at 240 V AC, line protection design, shunt trip release, 2 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-6EF32-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11106EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1110-6EF32-0HC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.25 W
3VA1110-6EF32-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1110-6EF32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-6EF32-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1110-6EF32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-6EF32-0HC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Its breaking capacity reaches 220 kA at 240 V AC, tapering to 154 kA at 415 V, 121 kA at 440 V, and 17 kA at both 500 V and 690 V — so the real-world SCCR you can claim depends entirely on your system voltage. The base switch variant is 3VA11106EF320AA0, meaning the core mechanism is shared across the 3VA1110 family — useful if you're stocking multiple frame sizes.

Rated 100 A at ambient temperatures up to 50 °C, the 3VA1110-6EF32-0HC0 begins derating above that: 98 A at 55 °C, 96 A at 60 °C, 94 A at 65 °C, and 91 A at 70 °C. Maximum power loss is 25 W, which factors into enclosure thermal calculations when grouping multiple breakers on a DIN rail.

Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — a 3-pole MCCB footprint that fits standard Siemens 3VA panelboards and distribution blocks. No undervoltage release is fitted; the shunt trip is the only auxiliary release, so if your safety circuit requires a UVR, you'll need a different variant or an add-on module.

Frequently asked questions

Does 3VA1110-6EF32-0HC0 include a shunt trip or undervoltage release?

It includes a shunt trip release (STL) for remote tripping, plus two HQ auxiliary switches. No undervoltage release is fitted — if your application requires a UVR, select a different variant or add an external module.

MPN