Skip to main content
Siemens 3VA1110-6EF32-0JH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-6EF32-0JH0 SENTRON MCCB, 100 A, 3-Pole, Line

MPN3VA1110-6EF32-0JH0

Siemens SENTRON 3VA1110-6EF32-0JH0, molded case circuit breaker, 3-pole, 100 A, TM240 overcurrent release, line protection, 220 kA at 240 V, shunt trip, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-6EF32-0JH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1110-6EF32-0JH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96 A
Current at 60 °C94 A
Current at 65 °C92 A
Current at 70 °C90 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 690 V17 kA
3VA1110-6EF32-0JH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1110-6EF32-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-6EF32-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1110-6EF32-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-6EF32-0JH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The interrupting ratings span 220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, and 17 kA at 690 V, which means this MCCB can handle high-fault-current scenarios typical of industrial transformer secondaries or large motor control centers without cascading upstream.

Thermal derating and ambient conditions

The breaker carries its full 100 A rating from 40 °C through 50 °C ambient, then derates to 96 A at 55 °C, 94 A at 60 °C, 92 A at 65 °C, and 90 A at 70 °C — a thermal curve that matters when the MCCB is enclosed in a non-ventilated panel near other heat sources.

Auxiliary and trip accessories

A voltage trigger is built in, and a mechanical trip indicator confirms the breaker has opened on fault — useful for quick visual checks during troubleshooting. The integrated auxiliary trip order code is 3VA9688-0BL32, which is the factory-fitted accessory; if that unit fails, order the same code for a drop-in replacement.

No undervoltage release, no phase-failure detection, no ground-fault monitoring, and no communication function are fitted on this variant — if those features are required for your BOM, a different 3VA order code in the same physical footprint should be selected.

Mechanical fit and panel integration

Dimensions are 130 mm height, 76.2 mm width, and 70 mm depth — the width matches the standard 3-pole MCCB footprint for Siemens 3VA frames, so it occupies the same DIN-rail or mounting-plate space as other 3VA 100 A units. Latching endurance is rated at 15 000 operations, which covers frequent switching in panel feeder duties but is not intended for motor-starting cycles.

MPN
3VA1110-6EF32-0JH0