Siemens 3VA1110-6EF36-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-6EF36-0AH0 MCCB, 100 A, 220 kA at 240 V

MPN3VA1110-6EF36-0AH0

Siemens SENTRON 3VA1110-6EF36-0AH0, 3-pole molded case circuit breaker, 100 A rated continuous current, TM240 thermal-magnetic release, 220 kA breaking capacity at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-6EF36-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1110-6EF36-0AH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C96 A
Current at 60 °C94 A
Current at 65 °C92 A
Current at 70 °C90 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 690 V17 kA
3VA1110-6EF36-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1110-6EF36-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-6EF36-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1110-6EF36-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-6EF36-0AH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1110-6EF36-0AH0 is a SENTRON molded case circuit breaker (MCCB) in a 3-pole configuration, rated for 100 A continuous current (Iu) with a TM240 thermal-magnetic overcurrent release. Its breaking capacity hits 220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, and 17 kA at 690 V — numbers that tell you this breaker is sized for high-fault industrial distribution, not light commercial subfeeds. The 70 mm depth and 76.2 mm width fit standard DIN-rail or panel-mount layouts, and the IP40 front protection means it's fine in a clean indoor enclosure but not for washdown zones.

This MCCB holds 100 A flat from 40 °C through 50 °C ambient. At 55 °C it derates to 96 A, at 60 °C to 94 A, at 65 °C to 92 A, and at 70 °C to 90 A. The 800 V rated insulation voltage (Ui) gives headroom for 690 V line-to-line systems, but the 17 kA SCCR at that voltage is the limiting factor for fault duty. Mechanical endurance is 15,000 cycles, which is standard for a line-protection MCCB in a distribution board that sees infrequent switching.

Frequently asked questions

What is the breaking capacity of 3VA1110-6EF36-0AH0 at different voltages?

220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, and 17 kA at 690 V. These are the interrupting ratings that govern selectivity and SCCR coordination in the distribution panel.

Where can I buy 3VA1110-6EF36-0AH0 and how is it quoted?

This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

Will 3VA1110-6EF36-0AH0 drop into a panel specified for 3VA1110-5EE32-0JA0?

Both are 3-pole, 100 A SENTRON MCCBs in the same 3VA platform, so the physical footprint (70 mm depth, 76.2 mm width, 130 mm height) is identical. The difference is in the overcurrent release: this unit uses a TM240 thermal-magnetic release, while the -5EE32 variant uses a different release curve. Verify the trip settings match your coordination study before swapping.

MPN
3VA1110-6EF36-0AH0