Skip to main content
Siemens 3VA1110-6GE46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-6GE46-0AA0 SENTRON MCCB, 100 A, 4-Pole, 220

MPN3VA1110-6GE46-0AA0
Active

Siemens SENTRON 3VA1110-6GE46-0AA0, 4-pole molded case circuit breaker, 100 A continuous, TM220 thermal-magnetic release, 220 kA interrupting at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1110-6GE46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1110-6GE46-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.25 W
3VA1110-6GE46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1110-6GE46-0AA0 — Construction & Connection
ParameterValue
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1110-6GE46-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1110-6GE46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1110-6GE46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

The interrupting ratings step down with voltage: 220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, and 17 kA at 500 V or 690 V — so the 240 V figure is the headline for high-fault panels, but at 480/500 V systems the 17 kA SCCR governs the coordination study. The 70 mm depth and 101.6 mm width mean it fits standard SENTRON panel footprints without gland-plate surprises.

Continuous current holds at 100 A up to 50 °C ambient, then derates to 98 A at 55 °C, 96 A at 60 °C, 94 A at 65 °C, and 91 A at 70 °C.

The 100 % N-conductor protection design means the neutral pole is rated for full phase current — no derating needed on the neutral path. Optional motor drive for remote switching is available as a field-addable accessory.

Frequently asked questions

What is the interrupting rating of 3VA1110-6GE46-0AA0 at 240 V?

220 kA at 240 V. At 415 V it is 154 kA, at 440 V it is 121 kA, and at 500 V or 690 V it drops to 17 kA — the voltage step matters for your coordination study.

Where can I buy 3VA1110-6GE46-0AA0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

MPN
3VA1110-6GE46-0AA0