Siemens 3VA1110-6MH32-0AG0 Circuit Breaker, 70kA @ 415V, 100

MPN3VA1110-6MH32-0AG0

Siemens 3VA1 IEC frame 160, breaking capacity class H, Icu=70kA @ 415V, 3-pole, starter protection TM120M, In=100A, short-circuit protection Ii=5...15 x In, nut keeper kit, 1 auxiliary switch HP, 1 trip alarm switch HP.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA1110-6MH32-0AG0 is a 3-pole IEC frame 160 molded case circuit breaker (MCCB) in breaking capacity class H, meaning it can interrupt 70 kA at 415 V — a rating sized for high-fault industrial distribution panels where upstream transformer capacity is substantial. The thermal-magnetic trip unit is the TM120M, set at 100 A, with short-circuit pickup adjustable 5 to 15 times In. This variant ships without overload protection (the TM120M provides only magnetic short-circuit protection), so it functions as a dedicated short-circuit protective device for motor starter circuits where overload protection is handled separately by the contactor/overload relay. The nut keeper kit, one auxiliary switch (HP), and one trip alarm switch (HP) are factory-fitted — no field assembly required for these accessories. The auxiliary switch signals the breaker's open/closed position; the trip alarm switch signals a fault trip, which is useful for remote annunciation in a PLC or SCADA system.

For motor starter duty, the TM120M's magnetic trip range (5–15 x In) means the instantaneous pickup can be set between 500 A and 1500 A, which is typical for coordinating with motor inrush without nuisance tripping on a 100 A motor circuit. Because this variant omits overload protection, it pairs with a separate overload relay (e.g., Siemens 3RU2 or 3RB3 series) in a Type 2 coordinated starter. The IEC frame 160 footprint mounts in standard Siemens 3VA1 panelboard and switchboard cutouts.

Frequently asked questions

What is the breaking capacity of this MCCB?

Breaking capacity class H, Icu = 70 kA at 415 V AC.

Does this breaker include overload protection?

No — the TM120M trip unit in this variant provides only magnetic short-circuit protection (Ii = 5–15 x In). Overload protection must be provided by a separate overload relay in the motor starter circuit.

What accessories are included with this order code?

Factory-fitted: nut keeper kit, one auxiliary switch HP, and one trip alarm switch HP.

MPN