Siemens 3VA1110-6MH32-0JC0 — Molded Case Circuit Breakers (MCCB)

3VA1110-6MH32-0JC0 Siemens 3VA1 MCCB, 100A, 70kA @ 415V

MPN3VA1110-6MH32-0JC0

Siemens 3VA1 IEC frame 160, breaking capacity class H, 3-pole MCCB, In=100A, Icu=70kA @ 415V AC, with TM120M thermal-magnetic release, shunt trip STL 110-127V DC/AC, 2 auxiliary switches HQ, nut keeper kit.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

Product identity and key ratings

The Siemens 3VA1110-6MH32-0JC0 is a 3VA1 series moulded-case circuit breaker on an IEC frame 160, rated 100 A continuous current (In) with a breaking capacity class H of Icu=70 kA at 415 V AC, 3-pole. The TM120M thermal-magnetic release provides starter protection; the adjustable short-circuit release (Ii) is set 5–15 × In. The unit ships with a shunt trip (STL) rated 110–127 V DC and AC 50/60 Hz, plus two HQ auxiliary switches and a nut keeper kit.

What the ratings mean for fit

The Icu=70 kA @ 415 V is the ultimate short-circuit breaking capacity — the breaker can safely interrupt a fault up to that level once and remain functional. For a 100 A feeder in a 415 V industrial panel, this provides substantial fault-current headroom, suitable for high-capacity distribution or motor control centres where available fault current is high. The adjustable Ii (5–15 × In) allows coordination with downstream motor starters: set at 5× for general distribution or 15× for high-inrush loads like large motors. The shunt trip (STL) operates on 110–127 V DC or AC 50/60 Hz, enabling remote tripping from an emergency stop circuit or a safety PLC output. The two HQ auxiliary switches provide status feedback (open/closed) to a control system or indication panel.

Deployment context

The 3VA1 frame mounts in standard switchboard or panelboard enclosures; the nut keeper kit simplifies panel-builder installation by retaining the mounting hardware during assembly. The shunt trip and auxiliary switches are factory-installed, reducing field wiring time.

Frequently asked questions

Where can I buy 3VA1110-6MH32-0JC0 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability confirmation.

What is the breaking capacity of this MCCB?

The ultimate breaking capacity Icu is 70 kA at 415 V AC, 3-pole, per the IEC frame 160 class H rating.

What accessories are included with 3VA1110-6MH32-0JC0?

It includes a shunt trip (STL) rated 110–127 V DC/AC 50/60 Hz, two HQ auxiliary switches, and a nut keeper kit.

MPN
3VA1110-6MH32-0JC0