Skip to main content
Siemens 3VA1110-6MH36-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-6MH36-0AH0 Circuit Breaker, 70kA @ 415V, 100

MPN3VA1110-6MH36-0AH0

Siemens 3VA1 IEC frame 160, breaking capacity class H, Icu=70kA @ 415V, 3-pole, starter protection TM120M, In=100A, short-circuit protection Ii=5...15 x In, clamp connection, 2 auxiliary switches HQ, 1 trip alarm switch HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

What this breaker is and what the ratings mean

The Siemens 3VA1110-6MH36-0AH0 is a 3-pole IEC molded-case circuit breaker on the 3VA1 platform, frame size 160, with a 100 A thermal-magnetic release (TM120M) configured for starter protection — meaning it provides short-circuit protection only, with no built-in overload function (that is handled by a separate motor starter or overload relay upstream). Breaking capacity class H delivers Icu = 70 kA at 415 V AC, which is the maximum short-circuit current the breaker can safely interrupt without damage. That rating places it in the high-capacity tier for this frame size — suitable for installations with high available fault current, such as large motor control centers or main distribution panels. The adjustable short-circuit release (Ii) spans 5 to 15 times In (500 A to 1500 A), letting you tune the magnetic trip threshold to the inrush characteristics of the connected load — typically a motor starter combination.

Lifecycle and sourcing reality

For a BOM-critical spare or a new panel build, the 3VA1110-6MH36-0AH0 can be sourced to order against an RFQ; availability and current pricing are confirmed at quote time.

Integration notes

Clamp-type terminals accept copper or aluminum conductors without lugs — a time-saver in panel wiring. The breaker ships with two auxiliary switches (HQ) and one trip alarm switch (HQ) pre-installed, covering status feedback and remote fault indication without additional accessories. Mounts on a standard DIN rail or directly to a backplate via the frame's integral fixing points. The 3VA1 platform shares accessory footprints with the broader Siemens 3VA family, so shunt trips, undervoltage releases, and motor operators are interchangeable.

Frequently asked questions

Where can I buy 3VA1110-6MH36-0AH0 and how do I get a price?

This breaker is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA1110-6MH36-0AH0?

Icu = 70 kA at 415 V AC, class H — high interrupting capacity for the 160 A frame.

What does the TM120M release mean on this breaker?

TM120M is a thermal-magnetic release rated 100 A, configured for starter protection (short-circuit only; overload protection is external). The magnetic trip is adjustable 5 to 15 times In.

MPN
3VA1110-6MH36-0AH0