Siemens 3VA1110-6MH36-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1110-6MH36-0BC0 SENTRON MCCB, 100 A, 3-Pole, 220

MPN3VA1110-6MH36-0BC0

Siemens SENTRON 3VA1110-6MH36-0BC0, molded case circuit breaker, 3-pole, 100 A rated current, 220 kA breaking capacity at 240 VAC, starter protection design with undervoltage release.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1110-6MH36-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11106MH360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1110-6MH36-0BC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.27.5 W

Protection & Trip Unit

3VA1110-6MH36-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM120M
Overcurrent protection functionI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1110-6MH36-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1110-6MH36-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1110-6MH36-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1110-6MH36-0BC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

MCCB for motor starter protection — 100 A continuous, 220 kA interrupting at 240 V

The Siemens SENTRON 3VA1110-6MH36-0BC0 is a 3-pole molded case circuit breaker (MCCB) designed specifically for starter protection — meaning its trip curve is shaped to coordinate with motor starting inrush while still providing short-circuit protection for the downstream contactor and overload relay. Rated 100 A continuous at ambient temperatures up to 50 °C without derating; above that it steps down to 98 A at 55 °C, 96 A at 60 °C, 94 A at 65 °C, and 91 A at 70 °C — so if the panel runs hot, the usable current drops, and that derated figure is what governs the motor full-load amp selection. Breaking capacity varies sharply with system voltage: 220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, and 7.5 kA at both 500 V and 690 V. At the higher voltages the fault-current capability is much lower — verify the available fault current at your system voltage before committing the BOM line.

Built-in undervoltage release and auxiliary switch complement

This MCCB ships with an undervoltage release (UVR) factory-installed — the UVR trips the breaker when supply voltage drops below a threshold, which is standard for motor starter circuits where you want automatic disconnection on brownout or phase loss. It also carries two factory-fitted auxiliary switches (HQ design) for remote status indication — one normally-open and one normally-closed contact per switch, giving four signal paths total to the PLC or panel指示灯. The basic switch core is order code 3VA11106MH360AA0 — useful to know if you ever need to order the bare switch assembly separately for a repair rather than replacing the whole breaker.

Panel fit and environmental limits

Dimensions are 130 mm height, 76.2 mm width (3 inches — standard MCCB footprint for a 3-pole frame), and 70 mm depth. The width matches the common 3-inch-per-pole spacing, so it drops into existing SENTRON mounting bases without panel modification. Rated insulation voltage is 800 V, so it's suitable for 690 V systems with margin. Operating temperature range is -25 °C to +70 °C; storage range is -40 °C to +80 °C. Maximum power loss at rated load is 27.5 W — factor that into enclosure thermal calculations if the panel is densely packed.

Frequently asked questions

Where can I buy 3VA1110-6MH36-0BC0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of 3VA1110-6MH36-0BC0 at different voltages?

Breaking capacity is 220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, and 7.5 kA at both 500 V and 690 V. The high-voltage capability is significantly lower — verify available fault current at your system voltage.

What compliance documentation does this brand provide for 3VA1110-6MH36-0BC0?

As a Siemens SENTRON MCCB, this part carries the standard IEC/UL certifications for the 3VA series. Specific documentation (RoHS, REACH, UL, IEC) is available from the manufacturer upon request — the evidence does not list individual cert marks on this variant.

Will 3VA1110-6MH36-0BC0 drop into a panel specified around 3VA1110-5ED36-0AC0 without rewiring?

Both are 3-pole SENTRON MCCBs on the same 76.2 mm width footprint, so the physical mounting and bus-bar spacing are identical. The key difference is the trip curve and accessory configuration — verify the 5ED36-0AC0's trip unit and auxiliary contacts match your coordination study before swapping.

MPN