Skip to main content
Siemens 3VA1112-1AA32-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-1AA32-0AF0 SENTRON Switch Disconnector, 125

MPN3VA1112-1AA32-0AF0

Siemens SENTRON 3VA1112-1AA32-0AF0, switch disconnector in MCCB design, 3-pole, In=125 A, no overload or short-circuit protection, IP40 front, 70 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1112-1AA32-0AF0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
3VA1112-1AA32-0AF0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C125 A
Current at 60 °C125 A
Current at 65 °C125 A
Current at 70 °C125 A
Power loss, max.38 W
3VA1112-1AA32-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1112-1AA32-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Motor drive optionYes
Auxiliary CO contacts2
3VA1112-1AA32-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1112-1AA32-0AF0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1112-1AA32-0AF0 is a 3-pole switch disconnector in a molded-case circuit breaker (MCCB) footprint, rated for 125 A continuous across the full operating temperature range from 40 °C to 70 °C — no derating needed up to the top end. It is a pure disconnect: no overload release, no short-circuit protection, no undervoltage release. That makes it a load-break switch for isolation and maintenance lockout, not a protective device. The front terminal busbar connection keeps wiring clean in a panel, and the IP40 front face suits enclosed switchgear where splash protection isn't required.

Insulation voltage is rated 800 V, operating voltage 690 V AC or 500 V DC, so it handles 480 V and 600 V class systems with margin. Mechanical life is 15,000 operating cycles typical, which is adequate for a disconnect that sees daily but not continuous switching.

This disconnect mounts in the same 76.2 mm wide, 130 mm tall, 70 mm deep envelope as the 3VA1 MCCB family — it drops into the same DIN-rail or screw-mount footprint. The front terminal busbar connection means you run the buswork straight in from the front, not the rear, which simplifies panel layout and busbar routing. The optional motor drive (listed as optional) allows remote switching if needed. At 38 W max power loss, it won't cook adjacent components, but leave a little breathing space in a dense row.

Frequently asked questions

Where can I buy 3VA1112-1AA32-0AF0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Will 3VA1112-1AA32-0AF0 drop into a panel specified around 3VA1112-5EE32-0AA0 without rewiring?

The physical footprint is identical — same 76.2 mm width, 130 mm height, 70 mm depth, and front terminal busbar connection. However, the 5EE32 variant is a molded-case circuit breaker with overcurrent protection; swapping to this disconnect removes all overload and short-circuit protection, so the protection scheme must be redesigned.

What is the continuous current rating of this disconnect?

125 A continuous, flat from 40 °C to 70 °C ambient — no derating required across the full operating temperature range.

MPN