Siemens 3VA1112-1AA32-0AG0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-1AA32-0AG0 SENTRON Switch Disconnector, 125

MPN3VA1112-1AA32-0AG0

Siemens SENTRON 3VA1112-1AA32-0AG0, switch disconnector in MCCB design, 3-pole, In=125 A, without overload or short-circuit protection, IP40 front, 70 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1112-1AA32-0AG0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
3VA1112-1AA32-0AG0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C125 A
Current at 60 °C125 A
Current at 65 °C125 A
Current at 70 °C125 A
Power loss, max.38 W
3VA1112-1AA32-0AG0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1112-1AA32-0AG0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Motor drive optionYes
Auxiliary CO contacts2
3VA1112-1AA32-0AG0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1112-1AA32-0AG0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1112-1AA32-0AG0 is a SENTRON switch disconnector in a molded-case circuit breaker (MCCB) footprint — 3-pole, rated 125 A continuous across the full ambient range from 40 °C to 70 °C without any derating. That flat thermal curve means you can mount it in a warm panel next to other heat sources and still count on the full 125 A. It is a disconnect-only device: no overload protection, no short-circuit protection, no undervoltage release. The job is isolating a load under load (it switches off under load, but does not trip on fault).

Ratings that matter for the panel

Rated insulation voltage 800 V, operating voltage 690 V AC and 500 V DC — covers common 400/480 VAC three-phase and 500 VDC battery or solar strings. Mechanical service life is 15 000 operating cycles, typical for a disconnect handle in a panel that sees daily switching. Depth is 70 mm, width 76.2 mm, height 130 mm; it fits the standard SENTRON 3VA frame-160 cutout.

Frequently asked questions

Where can I buy 3VA1112-1AA32-0AG0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the closest functional alternative to 3VA1112-1AA32-0AG0?

The 3VA1112-5EE32-0AA0 shares the same frame, footprint, and terminal arrangement but adds a TM220 overcurrent release (LI protection) — it is a true MCCB, not a disconnect. If you need overload and short-circuit protection, that is the sibling; if you need a pure disconnect, stick with this 3VA1112-1AA32-0AG0.

What are the key ratings of 3VA1112-1AA32-0AG0?

Rated 125 A continuous from 40 °C to 70 °C, insulation voltage 800 V, operating voltage 690 V AC / 500 V DC, 3-pole, IP40 front, depth 70 mm, width 76.2 mm, height 130 mm, mechanical service life 15 000 cycles.

MPN
3VA1112-1AA32-0AG0