Siemens 3VA1112-1AA32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-1AA32-0DH0 SENTRON Switch Disconnector, 125

MPN3VA1112-1AA32-0DH0

Siemens SENTRON 3VA1112-1AA32-0DH0, switch disconnector, IEC frame 160, 3-pole, SD100, In=125 A, busbar connection, with undervoltage release (UVR) 208-230 V AC, 2 auxiliary switches HQ + 1 trip alarm switch HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1112-1AA32-0DH0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1112-1AA32-0DH0 — Ratings
ParameterValue
Number of poles3
Power loss, max.38 W
3VA1112-1AA32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1112-1AA32-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1112-1AA32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1112-1AA32-0DH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1112-1AA32-0DH0 is a SENTRON 3VA1 switch disconnector in an IEC frame 160, 3-pole SD100 design, rated for 125 A continuous current without overload or short-circuit protection elements built in. It functions as a manually operated load-break switch for isolation and switching in distribution panels — think of it as the disconnect ahead of a motor feeder or a branch circuit where you need visible isolation but the overcurrent protection lives downstream in the MCCB or fuse. The 125 A rating on a 160 A frame gives thermal headroom for continuous loads at elevated ambient temperatures up to 70 °C.

Rated continuous current Iu of 125 A on the 160 A frame means this switch disconnector carries full load continuously without derating at 40 °C; above that, the thermal curve applies. The max rated operational voltage of 690 V AC 50/60 Hz covers 400 V and 480 V systems with margin; the DC rating of 500 V makes it usable in 250 V or 400 V DC bus applications common in data-center or solar combiner panels. When control voltage drops below about 170 V, the UVR trips the switch open. This is standard for safety interlocks or emergency-stop chains where a loss of control power must drop the load — common on conveyor lines or press feeders. The UVR has no leading contact, so it does not provide early break; the main contacts carry the full interruption. That gives three independent status signals: switch open/closed, switch open/closed (redundant or for two different loads), and a separate trip alarm that only changes state when the UVR or a manual trip opens the switch under fault. Useful for PLC inputs or status lamps without adding external relay blocks.

Mounts on a DIN rail via the integrated clip; the 76.2 mm width (roughly 4.5 modular units) and 70 mm depth fit standard 200 mm deep enclosures. Main circuit connection is busbar connection with front terminals — the busbar stabs insert from the front, so plan busbar routing behind the switch. The UVR and auxiliary switches are factory-fitted; no field wiring of internal coils. The nut keeper kit (included per the description) retains the busbar mounting nuts during maintenance.

Frequently asked questions

Where can I buy 3VA1112-1AA32-0DH0 and what is the lead time?

This part is sourced and quoted to order through independent distribution against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here.

What is the closest functional second-source to 3VA1112-1AA32-0DH0?

The peer 3VA1112-5EF32-0CA0 shares the same frame, poles, and 125 A rating but is a molded case circuit breaker (MCCB) with a TM240 thermal-magnetic trip unit and lug terminals — it provides overcurrent protection this switch disconnector lacks. It will not drop in as a direct substitute because the busbar connection and auxiliary contact fit differ.

Will 3VA1112-1AA32-0DH0 drop into a panel specified for 3VA1112-5EF32-0CA0 without rewiring?

No — the switch disconnector uses busbar connection (front terminals) while the MCCB peer uses lug terminals, so the main circuit wiring method is different. The auxiliary contact arrangement also differs (2+1 HQ vs. none), so control wiring would need re-termination.

What compliance documentation is available for 3VA1112-1AA32-0DH0?

As a SENTRON 3VA series product, it carries CE marking for the European market and is designed to IEC 60947-3 standards for switch-disconnectors. Specific RoHS, REACH, and UL documentation should be requested at quote time from the supplier.