Skip to main content
Siemens 3VA1112-1AA36-0AG0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA1112-1AA36-0AG0 Switch Disconnector, 125 A, 3-Pol

MPN3VA1112-1AA36-0AG0

SENTRON 3VA1112-1AA36-0AG0, switch disconnector in MCCB design, 3-pole, 125 A, 690 V AC, IP40 front, with 1 auxiliary switch and 1 trip alarm switch HP.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1112-1AA36-0AG0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
3VA1112-1AA36-0AG0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C125 A
Current at 60 °C125 A
Current at 65 °C125 A
Current at 70 °C125 A
Power loss, max.38 W
3VA1112-1AA36-0AG0 — Construction & Connection
ParameterValue
Main circuit connection typeTerminal connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1112-1AA36-0AG0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Motor drive optionYes
Auxiliary CO contacts2
3VA1112-1AA36-0AG0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1112-1AA36-0AG0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The SENTRON 3VA1112-1AA36-0AG0 is a 3-pole switch disconnector in a molded-case circuit breaker (MCCB) form factor, rated 125 A continuous across the full operating temperature range from 40 °C to 70 °C with no derating. It operates at 690 V AC or 500 V DC, making it suitable for line-side isolation in 400 V and 690 V industrial networks.

That simplifies panel sizing: if your load is 125 A or less at any ambient up to 70 °C, this switch disconnector handles it without a temperature correction factor. The 690 V AC rating covers both standard 400 V distribution and 690 V motor circuits common in heavy industrial and mining installations. This is a switch disconnector only — no overload or short-circuit protection (SD100 designation). It provides visible isolation for safe maintenance but requires upstream overcurrent protection.

Integration and deployment

The 76.2 mm width and 70 mm depth match the standard 3VA frame 160 footprint — drops into the same DIN-rail or panel-mount cutout as other 3VA1112 variants. The front-terminal connection keeps wiring accessible without removing the unit from the panel.

Frequently asked questions

What is the closest functional alternative to 3VA1112-1AA36-0AG0?

The 3VA1112-5EE32-0AA0 is a molded-case circuit breaker with the same frame, same 125 A rating, and same dimensions — but it includes thermal-magnetic overload protection (TM220 release) and short-circuit interruption, whereas the -1AA36-0AG0 is a switch disconnector only. The -5EE32-0AA0 also has a higher mechanical life (20 000 cycles vs 15 000) and no trip indicator. If your application requires only isolation, the -1AA36-0AG0 is the correct part; if you need overcurrent protection, the -5EE32-0AA0 is the functional equivalent with added protection.

Where can I buy 3VA1112-1AA36-0AG0?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

MPN
3VA1112-1AA36-0AG0