Skip to main content
Siemens 3VA1112-3ED42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-3ED42-0AA0 SENTRON MCCB, 125 A, 75.6 kA

MPN3VA1112-3ED42-0AA0
Active

Siemens SENTRON 3VA1112-3ED42-0AA0 molded case circuit breaker, 4-pole, TM210 overcurrent release, rated 125 A at 40 °C, breaking capacity 75.6 kA at 240 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1112-3ED42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA1112-3ED42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C122 A
Current at 60 °C120 A
Current at 65 °C117 A
Current at 70 °C114 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.28.1 W

Protection & Trip Unit

3VA1112-3ED42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1112-3ED42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1112-3ED42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1112-3ED42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1112-3ED42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

Line protection MCCB with TM210 release

The Siemens SENTRON 3VA1112-3ED42-0AA0 is a 4-pole molded case circuit breaker (MCCB) designed for line protection. It carries a TM210 thermal-magnetic overcurrent release, meaning the fixed thermal trip and magnetic short-circuit pickup are factory-set — no interchangeable trip units. Rated 125 A continuously at 40 °C, it handles the same current up to 50 °C without derating; above that the curve drops to 114 A at 70 °C. Breaking capacity is 75.6 kA at 240 V AC and 52.5 kA at 415 V AC, which covers most low-voltage distribution fault levels in North American and IEC panels. The 800 V rated insulation voltage (Ui) supports use in 480/277 V and 600 V systems with adequate margin.

Mounting and integration

The 101.6 mm wide (4 in), 130 mm tall, 70 mm deep footprint fits standard panel-mounted MCCB cutouts. Front IP40 protection keeps dust out of the enclosure face; the breaker itself is not rated for washdown environments. No undervoltage release or communication module is fitted on this variant — it is a straight thermal-magnetic device with no auxiliary electronics.

Frequently asked questions

What is the breaking capacity of 3VA1112-3ED42-0AA0?

75.6 kA at 240 V AC, 52.5 kA at 415 V AC, 32 kA at 440 V AC, and 11.9 kA at 500 V / 690 V AC.

Where can I buy 3VA1112-3ED42-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA1112-3ED42-0AA0