Specifications

3VA1112-3EF32-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1112-3EF32-0AF0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C120 A
Current at 60 °C117.5 A
Current at 65 °C115 A
Current at 70 °C112.5 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 690 V10.5 kA
3VA1112-3EF32-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1112-3EF32-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1112-3EF32-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1112-3EF32-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1112-3EF32-0AF0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

125 A MCCB with TM240 release — panel integration note

Breaking capacity is voltage-dependent: 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 10.5 kA at 690 V. That covers most low-voltage distribution panels in North American and European 400 V class systems. Thermal derating is published from 40 °C through 70 °C: the breaker holds full 125 A up to 50 °C, then steps down to 120 A at 55 °C, 117.5 A at 60 °C, 115 A at 65 °C, and 112.5 A at 70 °C.

Footprint and mounting

That 76.2 mm width is a standard 3-pole MCCB footprint — three 25.4 mm pole pitches — so it drops into the same DIN-rail or panel-mount cutout as other 125 A frame breakers.

Frequently asked questions

What is the breaking capacity of 3VA1112-3EF32-0AF0 at 415 V?

52.5 kA at 415 V. At 240 V it is 75.6 kA, at 440 V it is 32 kA, and at 690 V it is 10.5 kA.

What does the TM240 release designation mean on this MCCB?

TM240 is a thermal-magnetic fixed-trip release. The thermal element provides inverse-time overload protection; the magnetic element provides instantaneous short-circuit protection. It is not adjustable — the trip curve is factory-set for line protection duty.

Where can I buy 3VA1112-3EF32-0AF0 and get current pricing?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

Will 3VA1112-3EF32-0AF0 fit a panel designed for 3VA1112-5EF32-0CA0?

Both are 3-pole 125 A SENTRON MCCBs in the same 76.2 mm wide frame, so the physical footprint and bus-bar spacing are identical. The difference is the auxiliary contact configuration — the -0AF0 carries 1 auxiliary + 1 trip alarm switch (HQ), while the -0CA0 variant may differ. Check the auxiliary wiring diagram before drop-in replacement.

MPN
3VA1112-3EF32-0AF0