Siemens 3VA1112-3EF36-0JH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-3EF36-0JH0 SENTRON MCCB, 125 A, 3-Pole, Line

MPN3VA1112-3EF36-0JH0

Siemens SENTRON 3VA1112-3EF36-0JH0, molded case circuit breaker, 3-pole, 125 A, line protection, TM240 release, shunt trip, IP40 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1112-3EF36-0JH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1112-3EF36-0JH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C120 A
Current at 60 °C117.5 A
Current at 65 °C115 A
Current at 70 °C112.5 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 690 V10.5 kA

Protection & Trip Unit

3VA1112-3EF36-0JH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240

Construction & Connection

3VA1112-3EF36-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1112-3EF36-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA1112-3EF36-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1112-3EF36-0JH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Siemens 3VA1112-3EF36-0JH0 — 125 A SENTRON MCCB for Line Protection

The Siemens 3VA1112-3EF36-0JH0 is a SENTRON molded case circuit breaker (MCCB) rated for 125 A continuous current at 40 °C, 3-pole, configured for line protection. It carries a TM240 thermal-magnetic overcurrent release and an integrated shunt trip (STL) for remote tripping. The interrupting ratings climb to 75.6 kA at 240 V and 52.5 kA at 415 V — enough headroom for most distribution panels feeding motor control centers or lighting circuits. The 125 A rating holds flat from 40 °C through 50 °C, then derates to 120 A at 55 °C and 112.5 A at 70 °C. That means in a warm enclosure — say a non-ventilated panel near a furnace line — you size the load at 112.5 A, not the nameplate 125 A. The 800 V rated insulation voltage (Ui) covers 480 V and 600 V class systems with margin. This MCCB mounts on a DIN rail or panel base inside an IP40-front enclosure. The auxiliary contact block ships as 2 auxiliary switches plus 1 trip alarm switch (HQ configuration) — that gives you a separate signal for the breaker tripped state, useful for PLC alarming or a remote annunciator.

Interrupting Capacity and Selectivity

The interrupting ratings step down as system voltage rises: 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 10.5 kA at 690 V. That 10.5 kA figure at 690 V is the limiting case — if your panel feeds a 690 V drive bus, verify the available fault current stays under that number. The 52.5 kA at 415 V is the typical European distribution level; it coordinates well downstream of a 65 kA-rated main breaker.

Auxiliary and Trip Configuration

The shunt trip (STL) is factory-integrated — no field kit to install. The auxiliary contact version is 2 auxiliary switches + 1 trip alarm switch HQ, wired via the front terminals. The integrated auxiliary trip order code is 3VA9688-0BL32 if you need a spare or replacement module. No undervoltage release, no communication function, no phase failure detection — this is a basic line-protection breaker, not a smart metering device.

Environmental and Mechanical

Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. The latching endurance is rated at 15 000 cycles — that's the mechanical life for the switching mechanism. Dimensions are 130 mm height, 76.2 mm width, 70 mm depth, fitting standard 3-pole MCCB panel cutouts.

Frequently asked questions

What is the interrupting capacity of 3VA1112-3EF36-0JH0 at 415 V?

At 415 V the interrupting rating is 52.5 kA. At 240 V it is 75.6 kA, at 440 V it is 32 kA, and at 690 V it is 10.5 kA.

What auxiliary contacts come with this MCCB?

It ships with 2 auxiliary switches plus 1 trip alarm switch (HQ configuration). The integrated auxiliary trip module is order code 3VA9688-0BL32.

Where can I buy 3VA1112-3EF36-0JH0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.