Siemens 3VA1112-3EF36-0KC0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA1112-3EF36-0KC0 MCCB, 125 A, 75.6 kA at 240 V

MPN3VA1112-3EF36-0KC0

Siemens SENTRON 3VA1112-3EF36-0KC0, molded case circuit breaker, 3-pole, 125 A rated continuous current Iu, TM240 overcurrent release, line protection version, 75.6 kA breaking capacity at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1112-3EF36-0KC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1112-3EF36-0KC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C120 A
Current at 60 °C117.5 A
Current at 65 °C115 A
Current at 70 °C112.5 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 690 V10.5 kA

Protection & Trip Unit

3VA1112-3EF36-0KC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240

Construction & Connection

3VA1112-3EF36-0KC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1112-3EF36-0KC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1112-3EF36-0KC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1112-3EF36-0KC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

What this MCCB carries and where it fits

The Siemens SENTRON 3VA1112-3EF36-0KC0 is a 3-pole molded case circuit breaker (MCCB) rated for 125 A continuous current at 40 °C, with a TM240 thermal-magnetic overcurrent release — meaning the thermal pickup is fixed at 125 A and the magnetic short-circuit trip is calibrated for the TM240 curve. It is the line-protection version, so it is intended for feeder and main breaker duty in distribution panels, not for direct motor starting. Breaking capacity runs 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 10.5 kA at 690 V (–). At 690 V the 10.5 kA figure is the one that governs for high-voltage industrial grids — if your fault current at the panel exceeds that, you need a current-limiting upstream device or a higher-rated frame. Rated insulation voltage Ui is 800 V, so the breaker can be applied in 690 V systems without derating the insulation path. The front face carries IP40 protection — fine for a closed panel, not for washdown zones.

Auxiliaries and releases — what is on board

This unit ships with a shunt trip (STL) auxiliary release, part number 3VA9688-0BL33, and two auxiliary switches HQ. No undervoltage release, no ground-fault monitoring, no communication module, no phase-failure detection (–,). If you need remote trip via undervoltage or a ground-fault alarm, those are separate accessory slots on the 3VA platform — this base unit leaves them open. The trip indicator is not fitted — no mechanical flag on the front to show a trip event. For troubleshooting, you would rely on the shunt trip or the auxiliary contact state.

Thermal derating and ambient limits

Rated continuous current holds at 125 A from 40 °C through 50 °C (–). At 55 °C it drops to 120 A, at 60 °C to 117.5 A, at 65 °C to 115 A, and at 70 °C to 112.5 A (–). If the panel ambient runs above 50 °C, size the upstream conductor and load for the derated value — the breaker will still hold but you lose headroom. Operating temperature range is -25 °C to 70 °C (–); storage range is -40 °C to 80 °C (–). The storage limit governs handling and warehousing, not running conditions.

Panel fit — dimensions and mounting

The 3VA1112-3EF36-0KC0 measures 130 mm high, 76.2 mm wide, and 70 mm deep (–). The 76.2 mm width is a standard 3-pole MCCB footprint — it fits the same DIN-rail or screw-mount hole pattern as other SENTRON 3VA frames. If you are swapping out an older 3VA1112-5EF32-0CA0, the width and depth are identical; the difference is in the release and breaking capacity, not the mounting. Mechanical endurance is rated at 15 000 operations — fine for a main or feeder breaker cycled infrequently, not for a switching duty that sees daily open/close.

Frequently asked questions

What is the breaking capacity of 3VA1112-3EF36-0KC0 at 415 V?

52.5 kA at 415 V. At 240 V it is 75.6 kA, at 440 V it is 32 kA, and at 690 V it is 10.5 kA.

Does 3VA1112-3EF36-0KC0 include a shunt trip?

Yes, it is fitted with a shunt trip (STL) auxiliary release, part number 3VA9688-0BL33, plus two auxiliary switches HQ.

Will 3VA1112-3EF36-0KC0 drop into a panel specified for 3VA1112-5EF32-0CA0?

Yes, the mounting footprint (width 76.2 mm, depth 70 mm) is identical. The difference is in the overcurrent release and breaking capacity — the -5EF32 variant uses a different release curve. Check the release coordination for your specific load.

Where can I buy 3VA1112-3EF36-0KC0 and how is it quoted?

This part is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — stock and lead time are confirmed at quote time.

MPN
3VA1112-3EF36-0KC0