Siemens 3VA1112-4ED22-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-4ED22-0AA0 SENTRON MCCB, 125 A, 2-Pole, TM21

MPN3VA1112-4ED22-0AA0
Active

Siemens SENTRON 3VA1112-4ED22-0AA0, molded case circuit breaker, 2-pole, 125 A, TM210 thermal-magnetic trip, line protection, breaking capacity 121 kA at 240 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1112-4ED22-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA1112-4ED22-0AA0 — Ratings
ParameterValue
Number of poles2
Rated operational voltage Ue (AC)415 V
Rated insulation voltage Ui500 V
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C122 A
Current at 60 °C120 A
Current at 65 °C117 A
Current at 70 °C114 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Power loss, max.18.74 W

Protection & Trip Unit

3VA1112-4ED22-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1112-4ED22-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1112-4ED22-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0

Environmental

3VA1112-4ED22-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1112-4ED22-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width50.8 mm
Depth70 mm
Height (in)5.12 in
Width (in)2 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1112-4ED22-0AA0 is a 2-pole molded case circuit breaker (MCCB) rated 125 A continuous at 40 °C, with a TM210 thermal-magnetic trip unit. Breaking capacity reaches 121 kA at 240 V AC and 75.6 kA at 415 V AC — figures that govern fault-clearing capability in a distribution panel. The 70 mm depth and 50.8 mm width fit standard MCCB mounting footprints; IP40 on the front suits enclosed panel installation.

Thermal derating and trip unit

Rated 125 A at 40 °C, 45 °C, and 50 °C; derates to 122 A at 55 °C, 120 A at 60 °C, 117 A at 65 °C, and 114 A at 70 °C. The TM210 trip unit provides fixed thermal and magnetic settings for line protection — no adjustable long-time or short-time pickup. For DC applications, refer to the 3VA device manual for switching power limits.

Frequently asked questions

Where can I buy 3VA1112-4ED22-0AA0 and get a price?

This part is sourced and quoted to order against an RFQ. Submit a request for quote; availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA1112-4ED22-0AA0?

Breaking capacity is 121 kA at 240 V AC and 75.6 kA at 415 V AC.

What is the continuous current rating and how does temperature affect it?

Rated 125 A continuous at 40 °C, 45 °C, and 50 °C. Derates to 122 A at 55 °C, 120 A at 60 °C, 117 A at 65 °C, and 114 A at 70 °C.