Siemens 3VA1112-4ED32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-4ED32-0AA0 SENTRON MCCB, 125 A, 3-Pole, TM21

MPN3VA1112-4ED32-0AA0
Active

Siemens SENTRON 3VA1112-4ED32-0AA0, molded case circuit breaker, 3-pole, 125 A at 40 °C, TM210 overcurrent release, breaking capacity 121 kA at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1112-4ED32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1112-4ED32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C122 A
Current at 60 °C120 A
Current at 65 °C117 A
Current at 70 °C114 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.28.1 W
3VA1112-4ED32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1112-4ED32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1112-4ED32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1112-4ED32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1112-4ED32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Rated 125 A continuous at 40 °C ambient, it holds that rating through 50 °C before derating starts — 122 A at 55 °C, 120 A at 60 °C, 117 A at 65 °C, 114 A at 70 °C. That thermal curve matters if you're packing this breaker into a hot enclosure. Breaking capacity hits 121 kA at 240 V AC, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V. That's enough to clear a high-fault industrial service without upstream coordination headaches.

The TM210 release is fixed thermal-magnetic; you set the magnetic pickup via the rating plug, not a dial.

Frequently asked questions

Where can I buy the 3VA1112-4ED32-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here.

Will the 3VA1112-4ED32-0AA0 drop into a panel built for the 3VA1110-5ED32-0AA0?

Both are 3-pole SENTRON MCCBs with the same 70 mm depth and 76.2 mm width, so the physical footprint and bus-bar spacing are identical. The difference is the trip unit: the 3VA1112-4ED32-0AA0 carries a TM210 release rated 125 A, while the 3VA1110-5ED32-0AA0 uses a different TM release. If the panel was wired for 125 A, this one drops in without rewiring.

MPN