Skip to main content
Siemens 3VA1112-4ED36-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-4ED36-0AC0 SENTRON MCCB, 125A, 3-Pole, 121kA

MPN3VA1112-4ED36-0AC0

Siemens SENTRON 3VA1112-4ED36-0AC0, molded case circuit breaker, 3-pole, 125 A, TM210 overcurrent release, line protection, 121 kA at 240 V, 70 mm depth.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1112-4ED36-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11124ED360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1112-4ED36-0AC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C122 A
Current at 60 °C120 A
Current at 65 °C117 A
Current at 70 °C114 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.28.1 W

Protection & Trip Unit

3VA1112-4ED36-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1112-4ED36-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1112-4ED36-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1112-4ED36-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1112-4ED36-0AC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What the ratings mean for fit

The Siemens SENTRON 3VA1112-4ED36-0AC0 is a 3-pole molded case circuit breaker (MCCB) rated 125 A continuous at 40 °C, with the TM210 thermal-magnetic overcurrent release. That 125 A holds steady through 50 °C; above that it derates to 122 A at 55 °C and 114 A at 70 °C — so in a warm panel you lose about 9% of the headroom by the top of the operating range. The interrupting capacity is the real selector: 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V. If your fault current at the board is above 75 kA at 415 V, this breaker handles it without cascading upstream — that's the decision point for a high-capacity distribution panel.

Panel integration and footprint

At 70 mm deep, 76.2 mm wide, and 130 mm tall, this MCCB fits standard SENTRON mounting patterns — the 3-pole width matches the 76.2 mm (3-inch) module pitch common in Siemens switchboards. The 800 V rated insulation voltage (Ui) means it's rated for 690 V line-to-line systems without additional series isolation. Power loss is 28.1 W maximum at rated load, so factor that into enclosure thermal calculations if the panel is densely packed.

Auxiliary switch and accessories

Factory-fitted with 2 auxiliary switches (HQ design) — no separate add-on required for basic status feedback. No undervoltage release, no ground-fault monitoring, no trip indicator, and no communication function on this variant. The base switch part is 3VA11124ED360AA0, so if you need a bare breaker without auxiliaries, that's the order code to cross-check.

Frequently asked questions

What is the breaking capacity at 415 V for this MCCB?

75.6 kA at 415 V. That's the rating that governs most European 400 V distribution panels — sufficient for high-fault-current switchboards without upstream fusing.

What does the TM210 release designation mean?

TM210 is a fixed thermal-magnetic overcurrent release. 'TM' stands for thermal-magnetic; '210' indicates the release is sized for the breaker's 125 A frame. No electronic adjustment or communication capability — it's a straight thermal bimetal and magnetic coil trip unit.

Where can I buy 3VA1112-4ED36-0AC0?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial response.

What compliance documentation is available for this breaker?

As a Siemens SENTRON MCCB, it carries the standard IEC/UL certifications for the 3VA series. Specific compliance documentation (RoHS, REACH, UL, IEC) is provided with the shipment or available on request at quote time.

MPN
3VA1112-4ED36-0AC0