Skip to main content
Siemens 3VA1112-4EF32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-4EF32-0AA0 SENTRON MCCB, 125A, 3-Pole, TM240

MPN3VA1112-4EF32-0AA0
Active

Siemens SENTRON 3VA1112-4EF32-0AA0, molded case circuit breaker, 3-pole, 125 A, TM240 overcurrent release, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1112-4EF32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA1112-4EF32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C122 A
Current at 60 °C120 A
Current at 65 °C117 A
Current at 70 °C114 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.28.1 W

Protection & Trip Unit

3VA1112-4EF32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1112-4EF32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1112-4EF32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1112-4EF32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1112-4EF32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

SENTRON 3VA1112-4EF32-0AA0 — 125 A MCCB, TM240 Release

The Siemens 3VA1112-4EF32-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated for line protection, built around a TM240 thermal-magnetic overcurrent release and a 125 A continuous current at 40 °C. This 3-pole unit delivers a breaking capacity of 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V — giving you selectivity headroom across common distribution voltages. Current rating holds flat at 125 A from 40 °C to 50 °C, then derates to 122 A at 55 °C, 120 A at 60 °C, 117 A at 65 °C, and 114 A at 70 °C — useful when the breaker sits in a warm cabinet or near other heat sources. Rated insulation voltage is 800 V, and maximum power loss at rated current is 28.1 W. Front-face protection is IP40, meaning it's protected against tools and wires >1 mm but not sealed against moisture — standard for panel-mount gear.

Panel Fit & Mounting

Footprint is 76.2 mm wide, 130 mm tall, 70 mm deep — a standard 3-pole MCCB form factor that drops into most DIN-rail or screw-mount panel layouts without re-spacing. No undervoltage release, no communication module, no ground-fault monitoring on this variant — it's a straight line-protection breaker. If you need those options, you'd step up to a different 3VA suffix.

Coordination Note

The TM240 release is a fixed thermal-magnetic design — no interchangeable trip units, no electronic adjustments. Set it and forget it. The 121 kA SCCR at 240 V means it can be used as a main breaker in panels fed from high-capacity transformers, provided the let-through energy is coordinated with downstream branch devices.

Frequently asked questions

How do I get current pricing and availability for 3VA1112-4EF32-0AA0?

Submit an RFQ through this listing. The part is sourced and quoted to order through independent distribution; availability and current pricing are confirmed at quote time.

What are the key ratings for 3VA1112-4EF32-0AA0?

Continuous current 125 A at 40 °C, 3-pole, TM240 thermal-magnetic release. Breaking capacity: 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, 11.9 kA at 500 V and 690 V. Rated insulation voltage 800 V.

What is 3VA1112-4EF32-0AA0's listed depth?

Depth is 70 mm (2.76 in), width 76.2 mm (3 in), height 130 mm (5.12 in).

Will 3VA1112-4EF32-0AA0 drop into a panel specified around 5SQ2370-2YA05 without rewiring?

The 3VA1112-4EF32-0AA0 is a 3-pole MCCB in a standard 76.2 mm wide footprint. The 5SQ2370-2YA05 is a different product line; physical interchange depends on the panel's mounting hole pattern and bus bar spacing. Verify the existing cutout and terminal centers before ordering.

MPN
3VA1112-4EF32-0AA0