Siemens 3VA1112-4EF32-0AA0-ZD00 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-4EF32-0AA0-ZD00 Circuit Breaker, 125A, 36kA

MPN3VA1112-4EF32-0AA0-ZD00

Siemens 3VA1 series, IEC frame 160, breaking capacity class S, 3-pole, In=125A, Icu=36kA @ 415V, TM240 overload protection Ir=88A...125A, short-circuit protection Ii=5...10 x In, with nut keeper kit for DC Power OEM in China.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

The Siemens 3VA1112-4EF32-0AA0-ZD00 is a 3-pole IEC frame 160 molded case circuit breaker with a 125 A nominal rating and a 36 kA interrupting capacity at 415 V (breaking capacity class S). That Icu figure means it can safely clear a fault up to 36,000 A at 415 V without welding its contacts or rupturing the case — a key spec for panel builders sizing the upstream fault current. The TM240 thermal-magnetic trip unit gives adjustable overload protection from 88 A to 125 A (Ir), and short-circuit pickup (Ii) is fixed at 5 to 10 times In.

What the ratings mean for fit

The 125 A In and 36 kA Icu @ 415 V place this breaker squarely in the 'S' (standard) breaking capacity class for the 3VA1 frame. For a 415 V line, that Icu covers most industrial distribution panels fed by a transformer of 1,000 kVA or less. The TM240 trip unit's adjustable Ir (88–125 A) lets you fine-tune the overload threshold to match the downstream cable or busway rating without swapping the breaker. The nut keeper kit is a line-item detail for the DC Power OEM variant destined for China — it secures the terminal nuts against vibration in transport or high-vibration environments like a data-center power skid.

Panel integration

Mounts on a standard DIN rail or can be screw-fixed to a backplate. The 3VA1 frame is a compact IEC design — 105 mm wide per pole — so a 3-pole unit fits a 315 mm-wide DIN section. Leave 50 mm clearance above and below for arc-chute venting and cable bending radius. The nut keeper kit is pre-installed; no additional hardware needed for the line and load terminals.

Frequently asked questions

What is the interrupting rating of this breaker?

The 3VA1112-4EF32-0AA0-ZD00 has a rated ultimate short-circuit breaking capacity (Icu) of 36 kA at 415 V AC, which is the 'S' (standard) breaking capacity class for the 3VA1 IEC frame.

Where can I buy 3VA1112-4EF32-0AA0-ZD00 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What does the 'TM240, ATAM' designation mean on this breaker?

TM240 indicates a thermal-magnetic trip unit with a 240 A frame rating (the maximum continuous current the trip unit can handle). ATAM is an internal Siemens code for the adjustable overload (Ir) and fixed short-circuit (Ii) trip settings on this variant. The overload protection Ir is adjustable from 88 A to 125 A, and the short-circuit pickup Ii is fixed at 5 to 10 times In (625 A to 1,250 A).