Skip to main content
Siemens 3VA1112-4EF32-0DA0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA1112-4EF32-0DA0 MCCB, 125 A, 3-Pole, 121 kA at 24

MPN3VA1112-4EF32-0DA0

SENTRON 3VA1112-4EF32-0DA0, molded case circuit breaker (MCCB), 3-pole, 125 A, TM240 thermal-magnetic release, 121 kA at 240 V AC, undervoltage release, 70 mm depth × 76.2 mm width × 130 mm height.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1112-4EF32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11124EF320AA0
3VA1112-4EF32-0DA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C122 A
Current at 60 °C120 A
Current at 65 °C117 A
Current at 70 °C114 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.30.6 W
3VA1112-4EF32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1112-4EF32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1112-4EF32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1112-4EF32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1112-4EF32-0DA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The SENTRON 3VA1112-4EF32-0DA0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current of 125 A from 40 °C through 50 °C, derating to 122 A at 55 °C, 120 A at 60 °C, 117 A at 65 °C, and 114 A at 70 °C. The interrupting capacity reaches 121 kA at 240 V AC, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V — figures that define the fault-current headroom for panel coordination studies.

SCCR and selectivity

With 121 kA at 240 V and 75.6 kA at 415 V, this MCCB sits above typical distribution panel SCCR requirements for most commercial and light industrial installations. The undervoltage release (UVR) integrated into the auxiliary release design provides a clean trip on loss of control voltage — common in emergency-stop chains or undervoltage protection schemes. No communication module is fitted, so this is a standalone protective device, not a smart breaker.

That 3-inch width and 2.76-inch depth fit standard MCCB cutouts in SENTRON distribution panels and most third-party enclosures designed for 3-pole 125 A frames. The basic switch supplied is order code 3VA11124EF320AA0 — relevant if you need a replacement switching mechanism or are cross-referencing internal subassemblies. Maximum power loss is 30.6 W, which should be factored into enclosure thermal calculations, especially when multiple breakers are ganged.

Frequently asked questions

Who supplies 3VA1112-4EF32-0DA0 and how is it quoted for volume purchases?

This part is sourced and quoted to order against an RFQ through independent distribution channels; availability and current pricing are confirmed at quote time.

What is 3VA1112-4EF32-0DA0's listed depth (70 mm) on this component line?

The depth is 70 mm, with a width of 76.2 mm and height of 130 mm.

What are the key breaking capacity ratings for 3VA1112-4EF32-0DA0?

At 240 V it interrupts 121 kA, at 415 V it interrupts 75.6 kA, at 440 V it interrupts 52.5 kA, and at 500 V and 690 V it interrupts 11.9 kA (–).

MPN
3VA1112-4EF32-0DA0