Breaking capacity reaches 121 kA at 240 V, 75.6 kA at 415 V, and 52.5 kA at 440 V, so it handles high-fault utility feeds without cascading upstream. The 125 A rating holds flat from 40 °C to 50 °C; above that it derates gradually to 114 A at 70 °C. The 70 mm depth and 101.6 mm width fit standard MCCB panel cutouts.

Siemens 3VA1112-4GF46-0AA0 SENTRON MCCB, 125 A, 4-Pole
MPN3VA1112-4GF46-0AA0
Active
Siemens SENTRON 3VA1112-4GF46-0AA0, molded case circuit breaker, 4-pole, 125 A, TM240 overcurrent release, line protection design.
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Product designation | Molded case circuit breaker |
| Brand / range | SENTRON |
| Parameter | Value |
|---|---|
| Number of poles | 4 |
| Rated operational voltage Ue (AC) | 690 V |
| Rated insulation voltage Ui | 800 V |
| Current at 40 °C | 125 A |
| Current at 45 °C | 125 A |
| Current at 50 °C | 125 A |
| Current at 55 °C | 122 A |
| Current at 60 °C | 120 A |
| Current at 65 °C | 117 A |
| Current at 70 °C | 114 A |
| Switching capacity class | S |
| Breaking capacity at 240 V | 121 kA |
| Breaking capacity at 415 V | 75.6 kA |
| Breaking capacity at 440 V | 52.5 kA |
| Breaking capacity at 500 V | 11.9 kA |
| Breaking capacity at 690 V | 11.9 kA |
| Power loss, max. | 28.1 W |
| Parameter | Value |
|---|---|
| Overcurrent release (trip unit) type | TM240 |
| Overcurrent protection function | LI |
| Ground-fault monitoring | Without |
| Grounding protection function | No |
| Parameter | Value |
|---|---|
| Main circuit connection type | box terminal on both sides |
| Main circuit connector arrangement | Front terminal |
| Protection class (IP), front | IP40 |
| Parameter | Value |
|---|---|
| Undervoltage release | No |
| Voltage trigger | No |
| Trip indicator | No |
| Communication function | No |
| Measurement function | No |
| Motor drive option | Yes |
| Auxiliary CO contacts | 0 |
| Parameter | Value |
|---|---|
| Operating temperature, max. | 70 °C |
| Operating temperature, min. | -25 °C |
| Storage temperature, max. | 80 °C |
| Storage temperature, min. | -40 °C |
| Parameter | Value |
|---|---|
| Mechanical service life (operating cycles), typ. | 20 000 |
| Height | 130 mm |
| Width | 101.6 mm |
| Depth | 70 mm |
| Height (in) | 5.12 in |
| Width (in) | 4 in |
| Depth (in) | 2.76 in |
Product details
Frequently asked questions
What is the breaking capacity of 3VA1112-4GF46-0AA0 at 415 V?
75.6 kA at 415 V, with higher values at lower voltages (121 kA at 240 V) and lower values at higher voltages (11.9 kA at 500 V and 690 V).
Where can I buy 3VA1112-4GF46-0AA0 and how is it quoted?
This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.
MPN
3VA1112-4GF46-0AA0