Skip to main content
Siemens 3VA1112-5ED32-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-5ED32-0KA0 SENTRON MCCB, 125 A, 3-Pole, 187

MPN3VA1112-5ED32-0KA0

Siemens SENTRON, Molded case circuit breaker, 3VA1112-5ED32-0KA0, 3-pole, 125 A, TM210 release, shunt trip, IP40 front, interrupting 187 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1112-5ED32-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1112-5ED32-0KA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C120 A
Current at 60 °C117.5 A
Current at 65 °C115 A
Current at 70 °C112.5 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 690 V17 kA
3VA1112-5ED32-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VA1112-5ED32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1112-5ED32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1112-5ED32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1112-5ED32-0KA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

The Siemens 3VA1112-5ED32-0KA0 is a SENTRON 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current Iu of 125 A at 40 °C and an insulation voltage Ui of 800 V. Its interrupting capacity hits 187 kA at 240 V, 121 kA at 415 V, and 75.6 kA at 440 V — numbers that matter when coordinating downstream faults without cascading upstream.

The 125 A continuous rating holds steady up to 50 °C; above that it derates to 117.5 A at 60 °C and 112.5 A at 70 °C — check your enclosure ambient before sizing.

Frequently asked questions

Where can I buy 3VA1112-5ED32-0KA0 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

Will 3VA1112-5ED32-0KA0 drop into a panel that was specified around 3VA1112-5EF32-0CA0 without rewiring?

Both are 3-pole 125 A MCCBs on the same 3VA1112 frame, so the physical footprint — 76.2 mm wide, 130 mm tall, 70 mm deep — is identical. The key difference is the release: the -5ED32-0KA0 uses a TM210 thermal-magnetic release with a shunt trip, while the -5EF32-0CA0 carries a different release variant. Verify the control wiring for the shunt trip matches your panel's auxiliary circuit; the line and load lugs are in the same positions.

What compliance documentation does this brand provide for 3VA1112-5ED32-0KA0?

The SENTRON series is typically supplied with a CE declaration of conformity and UL/CSA listing documentation. Specific certificates (RoHS, REACH) are available from the manufacturer's support portal using the order code.

MPN
3VA1112-5ED32-0KA0