The Siemens 3VA1112-5EE32-0AA0 is a SENTRON molded case circuit breaker (MCCB) designed for line protection in distribution panels. It carries a 125 A continuous rating at 40 °C through 50 °C, then derates to 114 A at 70 °C — the thermal curve matters if your panel runs hot or you're pushing the bus near its limit. Breaking capacity is 187 kA at 240 V AC, dropping to 121 kA at 415 V and 75.6 kA at 440 V — still well above typical fault levels for most commercial and industrial services. At 500 V and 690 V it holds at 17 kA, which is adequate for motor branch circuits with proper coordination. The TM220 overcurrent release combines a thermal-magnetic trip with fixed settings — no adjustment dials, which simplifies specification but means you select the exact amp rating at ordering. No undervoltage release, no shunt trip, no communication module on this variant; it's a straight thermal-magnetic breaker for standard feeder protection. Front IP40 rating means it's protected against tools and small wires entering the front face, but not against water ingress — mount inside a panel, not in a washdown zone. Dimensions are 130 mm high, 76.2 mm wide, 70 mm deep; it fits a standard 3-pole MCCB footprint on DIN rail or panel-mount.

Siemens 3VA1112-5EE32-0AA0 SENTRON MCCB, 125 A, 3-Pole, TM22
MPN3VA1112-5EE32-0AA0
Active
Siemens SENTRON 3VA1112-5EE32-0AA0, molded case circuit breaker, 3-pole, TM220 overcurrent release, 125 A (40 °C), 187 kA at 240 V AC.
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026
Specifications
Identification
| Parameter | Value |
|---|---|
| Product designation | Molded case circuit breaker |
| Brand / range | SENTRON |
Ratings
| Parameter | Value |
|---|---|
| Number of poles | 3 |
| Rated operational voltage Ue (AC) | 690 V |
| Rated insulation voltage Ui | 800 V |
| Current at 40 °C | 125 A |
| Current at 45 °C | 125 A |
| Current at 50 °C | 125 A |
| Current at 55 °C | 122 A |
| Current at 60 °C | 120 A |
| Current at 65 °C | 117 A |
| Current at 70 °C | 114 A |
| Switching capacity class | M |
| Breaking capacity at 240 V | 187 kA |
| Breaking capacity at 415 V | 121 kA |
| Breaking capacity at 440 V | 75.6 kA |
| Breaking capacity at 500 V | 17 kA |
| Breaking capacity at 690 V | 17 kA |
| Power loss, max. | 28.1 W |
Protection & Trip Unit
| Parameter | Value |
|---|---|
| Overcurrent release (trip unit) type | TM220 |
| Overcurrent protection function | LI |
| Ground-fault monitoring | Without |
| Grounding protection function | No |
Construction & Connection
| Parameter | Value |
|---|---|
| Main circuit connection type | nut keeper kit on both ends |
| Main circuit connector arrangement | Front terminal |
| Protection class (IP), front | IP40 |
Accessories & Functions
| Parameter | Value |
|---|---|
| Undervoltage release | No |
| Voltage trigger | No |
| Trip indicator | No |
| Communication function | No |
| Measurement function | No |
| Motor drive option | Yes |
| Auxiliary CO contacts | 0 |
Environmental
| Parameter | Value |
|---|---|
| Operating temperature, max. | 70 °C |
| Operating temperature, min. | -25 °C |
| Storage temperature, max. | 80 °C |
| Storage temperature, min. | -40 °C |
Mechanical
| Parameter | Value |
|---|---|
| Mechanical service life (operating cycles), typ. | 20 000 |
| Height | 130 mm |
| Width | 76.2 mm |
| Depth | 70 mm |
| Height (in) | 5.12 in |
| Width (in) | 3 in |
| Depth (in) | 2.76 in |
Product details
Frequently asked questions
What is the breaking capacity of 3VA1112-5EE32-0AA0 at 240 V?
187 kA at 240 V AC, with 121 kA at 415 V and 75.6 kA at 440 V.
How do I get pricing and availability for 3VA1112-5EE32-0AA0?
Submit an RFQ through this listing — current pricing and stock status are confirmed at quote time through our sourcing network.
MPN
3VA1112-5EE32-0AA0