Skip to main content
Siemens 3VA1112-5EF32-0AG0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-5EF32-0AG0 SENTRON MCCB, 125 A, 3-Pole, Line

MPN3VA1112-5EF32-0AG0

Siemens SENTRON 3VA1112-5EF32-0AG0, molded case circuit breaker, 3-pole, 125 A rated continuous current, TM240 thermal-magnetic overcurrent release, line protection version, breaking capacity 187 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1112-5EF32-0AG0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA1112-5EF32-0AG0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C120 A
Current at 60 °C117.5 A
Current at 65 °C115 A
Current at 70 °C112.5 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 690 V17 kA
3VA1112-5EF32-0AG0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1112-5EF32-0AG0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1112-5EF32-0AG0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1112-5EF32-0AG0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1112-5EF32-0AG0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Siemens 3VA1112-5EF32-0AG0 — SENTRON MCCB, 125 A, Line Protection

Breaking capacity — what the voltage-specific ratings mean for fault clearing

Breaking capacity is stated per voltage level: 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V. For a 415 V industrial panel fed from a transformer with a 100 kA prospective fault current, this breaker clears it. At 690 V the margin is tighter — 17 kA limits it to lower-fault installations.

Thermal derating — continuous current across ambient temperature

Above that it derates: 120 A at 55 °C, 117.5 A at 60 °C, 115 A at 65 °C, and 112.5 A at 70 °C. Plan the load at the actual ambient, not the nameplate.

The trip indicator flag is present — visible through the front cover, useful for troubleshooting without opening the panel door.

Frequently asked questions

How is 3VA1112-5EF32-0AG0 quoted and supplied?

This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

What is the closest functional second-source for 3VA1112-5EF32-0AG0?

The 3VA1112-5EF32-0CA0 is a peer variant in the same SENTRON 3VA series. The -0AG0 carries the TM240 release with line protection; the -0CA0 differs in its release or accessory configuration. Both share the same 125 A frame, 3-pole layout, and physical footprint — but verify the release type and auxiliary contact spec before substituting.

What is the depth of 3VA1112-5EF32-0AG0?

The depth is 70 mm. Width is 76.2 mm, height is 130 mm.

Will 3VA1112-5EF32-0AG0 drop into a panel designed for 3VA1112-5EF32-0CA0?

Yes — both share the same 3VA frame dimensions (76.2 mm wide, 130 mm tall, 70 mm deep) and 3-pole layout. The mounting footprint and bus-bar spacing are identical. The difference is in the release or auxiliary contact configuration, not the mechanical fit.

MPN
3VA1112-5EF32-0AG0