Skip to main content
Siemens 3VA1112-5EF32-0KC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-5EF32-0KC0 SENTRON MCCB, 125 A, 3-Pole, 187

MPN3VA1112-5EF32-0KC0

Siemens SENTRON 3VA1112-5EF32-0KC0, molded case circuit breaker, 3-pole, 125 A, TM240 thermal-magnetic release, shunt trip (STL), 2 auxiliary switches HQ, line protection version, breaking capacity 187 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1112-5EF32-0KC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA11125EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1112-5EF32-0KC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C122 A
Current at 60 °C120 A
Current at 65 °C117 A
Current at 70 °C114 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.28.1 W
3VA1112-5EF32-0KC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1112-5EF32-0KC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1112-5EF32-0KC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1112-5EF32-0KC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1112-5EF32-0KC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Breaking capacity is the headline here: 187 kA at 240 V AC, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at both 500 V and 690 V.

The 3VA1112-5EF32-0KC0 measures 130 mm high, 76.2 mm wide, and 70 mm deep — a standard 3-pole MCCB footprint that drops into most SENTRON mounting plates and DIN-rail adapters without panel modification. The current derating curve starts above 55 °C — at 55 °C it still carries 122 A, at 70 °C it derates to 114 A. For a 125 A nominal load in a 50 °C panel, no derating is needed.

Auxiliary Release and Switching

The shunt trip (STL) design allows remote tripping via a control signal — typical for emergency-stop circuits or supervisory shutdown. The 2 auxiliary switches (HQ version) provide normally-open and normally-closed contacts for status monitoring without additional interposing relays.

Frequently asked questions

Where can I buy 3VA1112-5EF32-0KC0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability confirmation at quote time.

What is 3VA1112-5EF32-0KC0's breaking capacity at 240 V?

The breaking capacity is 187 kA at 240 V AC, with 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at both 500 V and 690 V.

Does this breaker include a shunt trip?

Yes, it is equipped with a shunt trip (STL) auxiliary release for remote tripping, plus 2 auxiliary switches (HQ configuration) for status feedback.

MPN
3VA1112-5EF32-0KC0