Skip to main content
Siemens 3VA1112-5EF36-0BA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-5EF36-0BA0 MCCB, 125A, 3-Pole, 187kA at 240V

MPN3VA1112-5EF36-0BA0

Siemens SENTRON 3VA1112-5EF36-0BA0, molded case circuit breaker, 3-pole, 125 A at 40 °C, TM240 overcurrent release, undervoltage release, 187 kA interrupting capacity at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1112-5EF36-0BA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11125EF360AA0

Ratings

3VA1112-5EF36-0BA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C122 A
Current at 60 °C120 A
Current at 65 °C117 A
Current at 70 °C114 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.30.6 W

Protection & Trip Unit

3VA1112-5EF36-0BA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1112-5EF36-0BA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1112-5EF36-0BA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1112-5EF36-0BA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1112-5EF36-0BA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

MCCB for line protection with UVR

The Siemens SENTRON 3VA1112-5EF36-0BA0 is a 3-pole molded case circuit breaker (MCCB) rated for 125 A at 40 °C, designed for line protection in industrial distribution panels. Its TM240 thermal-magnetic overcurrent release handles moderate overloads and short circuits, while the built-in undervoltage release (UVR) drops the breaker if supply voltage falls below the dropout threshold — a common requirement for safety circuits and motor feeder disconnects. The interrupting capacity is the standout: 187 kA at 240 V AC, 121 kA at 415 V, and still 17 kA at 690 V. That puts this breaker in the high-fault tier — suitable for main feeders or sub-distribution near large transformers where available fault current is severe. The 800 V rated insulation voltage confirms it can be used on 690 V systems with proper coordination.

Thermal derating and panel fit

Rated current holds flat at 125 A up to 50 °C ambient; above that it derates gradually to 114 A at 70 °C (the maximum operating temperature). In a crowded panel with poor airflow, factor in the 30.6 W max power loss when sizing cabinet cooling. Dimensions are 130 mm height × 76.2 mm width × 70 mm depth — a standard 3-pole MCCB footprint that fits most Siemens SENTRON panelboards and third-party enclosures with matching busbar centers. The 70 mm depth leaves clearance for wiring gutters and gland plates.

Frequently asked questions

Will 3VA1112-5EF36-0BA0 drop into a panel specified for 3VA1112-5EE32-0AA0 without rewiring?

Yes — both share the same 130 mm height, 76.2 mm width, and 70 mm depth, so the mechanical fit is identical. The busbar and lug positions are the same; no wiring changes needed.

MPN
3VA1112-5EF36-0BA0