Skip to main content
Siemens 3VA1112-5EF36-0BH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-5EF36-0BH0 SENTRON MCCB, 125 A, 3-Pole, Line

MPN3VA1112-5EF36-0BH0

Siemens SENTRON 3VA1112-5EF36-0BH0, molded case circuit breaker, 3-pole, 125 A rated continuous current Iu, line protection version with TM240 thermal-magnetic overcurrent release, interrupting capacity 187 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1112-5EF36-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1112-5EF36-0BH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C120 A
Current at 60 °C117.5 A
Current at 65 °C115 A
Current at 70 °C112.5 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 690 V17 kA
3VA1112-5EF36-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1112-5EF36-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1112-5EF36-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1112-5EF36-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1112-5EF36-0BH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Its TM240 thermal-magnetic overcurrent release handles both overload and short-circuit conditions without an external trip unit. The interrupting capacity scales with system voltage: 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V — so the same breaker can be specified across multiple distribution voltage levels as long as the available fault current stays under the applicable rating.

Thermal derating and ambient temperature profile

Above that, the breaker derates linearly: 120 A at 55 °C, 117.5 A at 60 °C, 115 A at 65 °C, and 112.5 A at 70 °C.

Integrated undervoltage release and auxiliary contact block

When line voltage drops below the release threshold, the breaker trips, which is standard for applications requiring under-voltage protection on motor feeders or safety circuits. A mechanical trip indicator is also present on the front.

Width is 76.2 mm (roughly 3 inches), depth is 70 mm, height is 130 mm.

Frequently asked questions

Where can I buy 3VA1112-5EF36-0BH0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote with traceability to the lot.

What is the interrupting capacity of 3VA1112-5EF36-0BH0 at 415 V?

121 kA at 415 V. The interrupting capacity also covers 187 kA at 240 V, 75.6 kA at 440 V, and 17 kA at 690 V.

What does the TM240 release designation mean?

TM240 is a thermal-magnetic overcurrent release — the thermal element handles overload protection, the magnetic element handles short-circuit protection. It is fixed (non-interchangeable) and set for line protection duty.

Does this MCCB include an undervoltage release?

Yes, it includes an integrated undervoltage release (UVR) as the auxiliary release. When line voltage drops below the release threshold, the breaker trips.

MPN
3VA1112-5EF36-0BH0