Skip to main content
Siemens 3VA1112-5GF46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-5GF46-0AA0 SENTRON MCCB, 125 A, 4-Pole, 187

MPN3VA1112-5GF46-0AA0
Active

Siemens SENTRON 3VA1112-5GF46-0AA0, molded case circuit breaker, 4-pole, 125 A, TM240 overcurrent release, breaking capacity 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1112-5GF46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1112-5GF46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C122 A
Current at 60 °C120 A
Current at 65 °C117 A
Current at 70 °C114 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.28.1 W
3VA1112-5GF46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1112-5GF46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1112-5GF46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1112-5GF46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1112-5GF46-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

125 A, 4-pole MCCB with TM240 release

The TM240 thermal-magnetic release provides fixed overload and short-circuit protection, with no undervoltage release or trip indicator fitted on this variant. Breaking capacity is 187 kA at 240 V AC, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at both 500 V and 690 V — figures that give solid selectivity headroom in high-fault-current panels. Current rating holds at 125 A up to 50 °C ambient; above that it derates to 122 A at 55 °C, 120 A at 60 °C, 117 A at 65 °C, and 114 A at 70 °C. Maximum power loss is 28.1 W.

Dimensions are 101.6 mm wide, 130 mm high, 70 mm deep — a 4-pole MCCB that fits standard SENTRON 3VA panel cutouts and busbar systems. Front protection is IP40; the body is designed for screw-mounting in enclosed switchboards.

Frequently asked questions

Will 3VA1112-5GF46-0AA0 drop into a panel specified around 3VA1110-5ED36-0AC0 without rewiring?

Both are 4-pole SENTRON 3VA breakers, but the 3VA1112-5GF46-0AA0 is a 125 A frame with TM240 release, while the 3VA1110-5ED36-0AC0 is a lower-current variant. The physical footprint and mounting pattern are the same across the 3VA family, so panel cutouts and busbar positions match. Verify the current rating and trip curve against your load before swapping — the breaker itself will fit the same footprint.

What compliance documentation does Siemens provide for 3VA1112-5GF46-0AA0?

Standard Siemens documentation for the SENTRON 3VA series includes the device manual, CE declaration of conformity, and UL/CSA certification data. RoHS and REACH compliance declarations are available from Siemens support.

MPN
3VA1112-5GF46-0AA0