Siemens 3VA1112-5MH32-0AE0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-5MH32-0AE0 Circuit Breaker, 125A, 55kA @ 415

MPN3VA1112-5MH32-0AE0

Siemens 3VA1 IEC frame 160, breaking capacity class M, 3-pole, 125A, Icu=55kA @ 415V, starter protection TM120M, short-circuit protection Ii=5...15 x In, with nut keeper kit and 4 auxiliary switches HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

What this breaker is and where it fits

The Siemens 3VA1112-5MH32-0AE0 is a 3-pole IEC frame 160 molded-case circuit breaker rated 125 A continuous, with a breaking capacity of 55 kA at 415 V (class M). It is configured for motor starter protection using a TM120M thermal-magnetic trip unit — note the TM prefix means thermal-magnetic, not electronic — and the adjustable short-circuit pickup Ii spans 5 to 15 times In. The unit ships with a nut keeper kit and four HQ auxiliary switches pre-installed, so it arrives ready for panel wiring without sourcing add-on blocks separately.

What the ratings mean for your panel

The 55 kA Icu at 415 V is the ultimate short-circuit breaking capacity — the breaker can safely interrupt a fault of that magnitude once and remain functional. For a panel with a transformer-fed 415 V supply and a fault current below that threshold, this breaker provides adequate SCCR headroom without cascading upstream. The TM120M trip unit is sized for motor starting duty: the thermal element tracks motor heating during start and running, while the magnetic element handles the inrush without nuisance tripping. The adjustable Ii (5–15 x In) lets you coordinate with downstream contactors and overload relays — set it toward the lower end for a tight short-circuit protection band on a known load, or toward the upper end if the motor's locked-rotor current demands it.

Deployment context

Mounts on a DIN rail or panel-mount in a standard distribution or motor control center enclosure. The four HQ auxiliary switches provide status feedback (open/closed/tripped) to a PLC or indication lamp without requiring a separate auxiliary contact block. The nut keeper kit simplifies busbar or cable lug termination — the nuts stay captive during wiring, which saves time on a panel with multiple breakers.

Frequently asked questions

What is the breaking capacity of this breaker?

The ultimate breaking capacity Icu is 55 kA at 415 V, which is class M for the 3VA1 frame. This means it can safely interrupt a fault current up to 55 kA once without damage.

Where can I buy the 3VA1112-5MH32-0AE0 and how is it quoted?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What does the TM120M trip unit mean?

TM120M is a thermal-magnetic trip unit rated 125 A continuous. The thermal element provides overload protection; the magnetic element provides short-circuit protection with an adjustable pickup Ii from 5 to 15 times In (625 A to 1875 A). It is designed for motor starter applications where the breaker protects the cable and motor against short circuits, while a separate overload relay handles running overloads.

Does this breaker include auxiliary switches?

Yes, it ships with four HQ auxiliary switches pre-installed. These provide status contacts for remote indication or PLC input without needing a separate accessory block.