Skip to main content
Siemens 3VA1112-6ED42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-6ED42-0AA0 SENTRON MCCB, 125 A, 4-Pole, 220

MPN3VA1112-6ED42-0AA0
Active

Siemens SENTRON 3VA1112-6ED42-0AA0, molded case circuit breaker, 4-pole, 125 A, TM210 release, 220 kA at 240 V, 70 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1112-6ED42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1112-6ED42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C122 A
Current at 60 °C120 A
Current at 65 °C117 A
Current at 70 °C114 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V76 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.28.1 W
3VA1112-6ED42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1112-6ED42-0AA0 — Construction & Connection
ParameterValue
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1112-6ED42-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1112-6ED42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1112-6ED42-0AA0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.1 in
Width (in)4 in
Depth (in)2.8 in

Product details

MCCB for high-fault line protection

Its interrupting capacity reaches 220 kA at 240 V, 154 kA at 415 V, and 76 kA at 440 V — figures that place it squarely in the high-fault category for industrial main feeders and large sub-distribution panels. The 125 A rating holds flat from 40 °C through 50 °C ambient, then derates to 122 A at 55 °C and 114 A at 70 °C.

At 70 mm deep, 101.6 mm wide, and 130 mm tall, this 4-pole MCCB fits standard SENTRON mounting patterns. If you are packing multiple breakers in a compact panel, that heat must be factored into the cabinet ventilation or cooling specification.

Lifecycle and compliance posture

The TM210 release designates a thermal-magnetic trip unit with fixed settings — no interchangeable electronic trip module. This simplifies specification for line-protection applications where coordination studies are already locked, but limits field adjustability if load characteristics change later.

Frequently asked questions

Where can I buy 3VA1112-6ED42-0AA0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial response.

What is the interrupting capacity of 3VA1112-6ED42-0AA0 at 240 V?

220 kA at 240 V, with 154 kA at 415 V and 76 kA at 440 V — suitable for high-fault-current industrial mains.

MPN
3VA1112-6ED42-0AA0