Siemens 3VA1112-6EF32-0CC0 SENTRON MCCB, 125 A, 3-Pole, 220

MPN3VA1112-6EF32-0CC0

Siemens SENTRON 3VA1112-6EF32-0CC0, 3-pole molded case circuit breaker, 125 A at 40 °C, 220 kA breaking capacity at 240 V, with undervoltage release and 2 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1112-6EF32-0CC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11126EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1112-6EF32-0CC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C122 A
Current at 60 °C120 A
Current at 65 °C117 A
Current at 70 °C114 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.30.6 W
3VA1112-6EF32-0CC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1112-6EF32-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1112-6EF32-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1112-6EF32-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1112-6EF32-0CC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

125 A line-protection MCCB with UVR and aux switches

The Siemens SENTRON 3VA1112-6EF32-0CC0 is a 3-pole molded case circuit breaker rated for 125 A continuous current at 40 °C through 50 °C, with a slight thermal derating curve down to 114 A at 70 °C. Its headline breaking capacity hits 220 kA at 240 V AC, dropping to 154 kA at 415 V and 75.6 kA at 440 V — numbers that matter when you're coordinating downstream branch protection and need the upstream device to clear a high-fault bolted short without cascading.

At 240 V the 220 kA SCCR puts this breaker in the high-fault tier — it's sized for main or feeder positions where the available fault current from the utility transformer or upstream generator is substantial. The 154 kA at 415 V and 75.6 kA at 440 V still cover most industrial distribution panels. Maximum power loss of 30.6 W at full load gives you a number for panel thermal budgeting.

Built-in undervoltage release and auxiliary switching

The two HQ auxiliary switches provide position feedback (open/closed) for PLC inputs or status lamps. The trip indicator is absent, so you'll rely on the aux switch state or visual breaker handle position to confirm tripped status.

Dimensions are 130 mm height, 76.2 mm width (3 inches), and 70 mm depth. The 3-pole form factor fits standard SENTRON panel cutouts and busbar systems. The unit accepts lug or busbar connections on line and load sides; the UVR coil terminals are separate low-voltage connections.

Frequently asked questions

Where can I buy 3VA1112-6EF32-0CC0 and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an inquiry for your specific quantity and delivery window.

What is the breaking capacity of this MCCB at different voltages?

220 kA at 240 V, 154 kA at 415 V, 75.6 kA at 440 V, and 17 kA at both 500 V and 690 V.

Does 3VA1112-6EF32-0CC0 include an undervoltage release?

Yes, it ships with a factory-fitted undervoltage release (UVR) and two HQ auxiliary switches for status feedback.

What are the physical dimensions of this breaker?

130 mm height, 76.2 mm width (3 inches), and 70 mm depth.