Skip to main content
Siemens 3VA1112-6EF32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-6EF32-0DA0 SENTRON MCCB, 125A, 3-Pole, TM240

MPN3VA1112-6EF32-0DA0

Siemens SENTRON 3VA1112-6EF32-0DA0, molded case circuit breaker, 3-pole, TM240 thermal-magnetic release, 125 A at 40 °C, line protection, with undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1112-6EF32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11126EF320AA0
3VA1112-6EF32-0DA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C122 A
Current at 60 °C120 A
Current at 65 °C117 A
Current at 70 °C114 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.30.6 W
3VA1112-6EF32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1112-6EF32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1112-6EF32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1112-6EF32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1112-6EF32-0DA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

SENTRON 3VA1112-6EF32-0DA0 — 125 A MCCB with undervoltage release

It carries a TM240 thermal-magnetic trip unit and an integrated undervoltage release (UVR), so it drops the load if supply voltage falls below the release threshold — useful for motor branch circuits or safety disconnects where you want automatic shutdown on loss of control power.

Breaking capacity across voltage levels

Breaking capacity varies significantly with system voltage: 220 kA at 240 V, 154 kA at 415 V, 75.6 kA at 440 V, and 17 kA at both 500 V and 690 V. That 220 kA at 240 V is high enough for most North American 240/120 V panelboards with large transformer feeds; the 17 kA at 690 V still covers standard 690 V industrial distribution.

Current derating and thermal limits

Rated 125 A from 40 °C through 50 °C ambient, then derates to 122 A at 55 °C, 120 A at 60 °C, 117 A at 65 °C, and 114 A at 70 °C. Maximum power loss is 30.6 W at rated current, which matters for enclosure thermal calculations.

Undervoltage release and trip features

No voltage trigger or communication function on this variant. No trip indicator. The TM240 release is thermal-magnetic: thermal element for overload protection, magnetic for short-circuit. This is a line-protection design, not a motor-protection or ground-fault version.

Width 76.2 mm (3 in), height 130 mm (5.12 in), depth 70 mm (2.76 in).

Frequently asked questions

Where can I buy 3VA1112-6EF32-0DA0 and how do I get a price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — submit an RFQ for a firm quote.

Will 3VA1112-6EF32-0DA0 drop into a panel specified around 3VA1112-5EE32-0AA0 without rewiring?

Both are 3-pole SENTRON MCCBs in the same 76.2 mm wide footprint, so the physical mounting and busbar connection are identical. The difference is the trip unit and accessories: this one has a TM240 release with an undervoltage release; the 5EE32 variant uses a different release. If the panel wiring is sized for 125 A and the control circuit expects a UVR, this drops in without rewiring. Verify the trip curve and auxiliary contact scheme against the original BOM.

What compliance documentation does this brand provide for 3VA1112-6EF32-0DA0?

As a Siemens SENTRON product, it carries CE marking for the European market and is designed to IEC 60947-2. UL/CSA listings are typical for this series, though not explicitly confirmed in the spec record. RoHS and REACH declarations are available from Siemens documentation.

MPN
3VA1112-6EF32-0DA0