Skip to main content
Siemens 3VA1112-6EF36-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-6EF36-0DH0 SENTRON MCCB, 125A, 220kA at 240V

MPN3VA1112-6EF36-0DH0

Siemens SENTRON 3VA1112-6EF36-0DH0, 3-pole molded case circuit breaker, 125 A rated, 220 kA breaking capacity at 240 V AC, line protection design with undervoltage release and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1112-6EF36-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11126EF360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1112-6EF36-0DH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C122 A
Current at 60 °C120 A
Current at 65 °C117 A
Current at 70 °C114 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.30.6 W

Protection & Trip Unit

3VA1112-6EF36-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1112-6EF36-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1112-6EF36-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA1112-6EF36-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1112-6EF36-0DH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1112-6EF36-0DH0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current of 125 A at 40 °C and a rated insulation voltage of 800 V. Its breaking capacity is 220 kA at 240 V, stepping down to 154 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 500 V and 690 V — the high interrupt rating at 240 V makes this a strong candidate for low-voltage distribution where fault current is severe.

Current derating and thermal management

The 125 A rating holds flat from 40 °C through 50 °C, then derates to 122 A at 55 °C, 120 A at 60 °C, 117 A at 65 °C, and 114 A at 70 °C. Maximum power loss is 30.6 W — factor that into enclosure heat rise if the breaker is panel-mounted alongside other heat sources.

Auxiliary and release configuration

This variant ships with an undervoltage release (UVR) and a complement of 2 auxiliary switches plus 1 trip alarm switch (HQ). The trip indicator is present. If your circuit requires undervoltage protection for motor starters or safety disconnects, the UVR is already built in — no separate add-on needed.

Dimensions and panel fit

The breaker measures 130 mm high, 76.2 mm wide, and 70 mm deep. The 3-pole width is standard for SENTRON 3VA switchboard and distribution panel layouts — verify busbar spacing and mounting footprint against your existing panel cutout.

Frequently asked questions

What is the breaking capacity of 3VA1112-6EF36-0DH0 at different voltages?

Breaking capacity is 220 kA at 240 V, 154 kA at 415 V, 75.6 kA at 440 V, and 17 kA at both 500 V and 690 V.

How do I get current pricing and availability for 3VA1112-6EF36-0DH0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your quantity and delivery timeline.

What auxiliary switches and releases come on this breaker?

It includes 2 auxiliary switches plus 1 trip alarm switch (HQ), and an undervoltage release (UVR) is built in.

MPN
3VA1112-6EF36-0DH0