Siemens 3VA1112-6GE42-0AA0-ZD00 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-6GE42-0AA0-ZD00 125A 70kA 4P MCCB

MPN3VA1112-6GE42-0AA0-ZD00

Siemens 3VA1 IEC frame 160, 4-pole MCCB, breaking capacity class H, 125A, 70kA @ 415V, TM220 thermal-magnetic trip, ATFM, 100% N conductor protection, nut keeper kit, DC Power OEM variant.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

Breaking capacity and trip curve

The 3VA1112-6GE42-0AA0-ZD00 is a 4-pole IEC frame 160 molded case circuit breaker rated 125 A continuous with a 70 kA interrupting capacity at 415 V (breaking capacity class H). That 70 kA rating means it can safely clear a bolted fault at the line terminals without rupturing — critical for high-fault installations like transformer secondaries or large motor control centers where available fault current exceeds 50 kA. The TM220 thermal-magnetic trip unit provides overload protection adjustable from 88 A to 125 A (Ir) and a fixed short-circuit pickup of 10 x In (Ii = 1250 A). The 100% N conductor protection means the neutral pole is fully rated and trips simultaneously with the phase poles — required on 4-wire systems where the neutral carries unbalanced load current and must be switched, not just connected. The ATFM designation indicates the trip unit is adjustable thermal, fixed magnetic.

OEM variant and deployment context

This order code carries the -ZD00 suffix, a Siemens OEM variant configured for DC Power applications in China. The nut keeper kit is included in the package — a detail that saves panel builders from sourcing a separate mounting kit. The breaker mounts on a standard DIN rail or directly to a backplate via the frame's bolt-on lugs. The 4-pole form factor suits it for three-phase + neutral distribution panels, UPS output breakers, or generator paralleling gear where neutral switching and protection are mandatory. The 70 kA class H rating gives selectivity headroom downstream of a larger main breaker.

Lifecycle and sourcing posture

For a critical-spare holding or a BOM line that needs this exact OEM-suffix breaker, the part is sourced and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time through independent distribution. No spare, no sleep — this one is worth keeping one in the cabinet if the install is remote or the line has no redundancy.

Frequently asked questions

What is the interrupting rating of this MCCB?

70 kA at 415 V AC, breaking capacity class H per IEC 60947-2. This is the maximum fault current the breaker can safely interrupt at that voltage.

What does the TM220 trip unit mean?

TM220 is a thermal-magnetic trip with adjustable thermal overload (Ir = 88 A to 125 A) and a fixed magnetic short-circuit pickup at 10 x In (1250 A). The 220 indicates the frame size and trip class.

Where can I buy 3VA1112-6GE42-0AA0-ZD00?

This part is sourced and quoted to order against an RFQ through independent industrial distribution. Availability and current pricing are confirmed at quote time.

Does this breaker include neutral protection?

Yes, the 4-pole design provides 100% N conductor protection — the neutral pole is fully rated and trips with the phase poles.

MPN
3VA1112-6GE42-0AA0-ZD00