Siemens 3VA1112-6GE42-0AA0-ZD00 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-6GE42-0AA0-ZD00 125A 70kA 4P MCCB

MPN3VA1112-6GE42-0AA0-ZD00

Siemens 3VA1 IEC frame 160, 4-pole MCCB, breaking capacity class H, 125A, 70kA @ 415V, TM220 thermal-magnetic trip, ATFM, 100% N conductor protection, nut keeper kit, DC Power OEM variant.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

Breaking capacity and trip curve

The 3VA1112-6GE42-0AA0-ZD00 is a 4-pole IEC frame 160 molded case circuit breaker rated 125 A continuous with a 70 kA interrupting capacity at 415 V (breaking capacity class H). The TM220 thermal-magnetic trip unit provides overload protection adjustable from 88 A to 125 A (Ir) and a fixed short-circuit pickup of 10 x In (Ii = 1250 A). The 100% N conductor protection means the neutral pole is fully rated and trips simultaneously with the phase poles — required on 4-wire systems where the neutral carries unbalanced load current and must be switched, not just connected. The ATFM designation indicates the trip unit is adjustable thermal, fixed magnetic.

OEM variant and deployment context

This order code carries the -ZD00 suffix, a Siemens OEM variant configured for DC Power applications in China. The 4-pole form factor suits it for three-phase + neutral distribution panels, UPS output breakers, or generator paralleling gear where neutral switching and protection are mandatory. The 70 kA class H rating gives selectivity headroom downstream of a larger main breaker.

No spare, no sleep — this one is worth keeping one in the cabinet if the install is remote or the line has no redundancy.

Frequently asked questions

What is the interrupting rating of this MCCB?

70 kA at 415 V AC, breaking capacity class H per IEC 60947-2. This is the maximum fault current the breaker can safely interrupt at that voltage.

What does the TM220 trip unit mean?

TM220 is a thermal-magnetic trip with adjustable thermal overload (Ir = 88 A to 125 A) and a fixed magnetic short-circuit pickup at 10 x In (1250 A). The 220 indicates the frame size and trip class.

Where can I buy 3VA1112-6GE42-0AA0-ZD00?

This part is sourced and quoted to order against an RFQ through independent industrial distribution. Availability and current pricing are confirmed at quote time.

Does this breaker include neutral protection?

Yes, the 4-pole design provides 100% N conductor protection — the neutral pole is fully rated and trips with the phase poles.