Skip to main content
Siemens 3VA1112-6MH32-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-6MH32-0KA0 Circuit Breaker, 125A, 70kA @ 415

MPN3VA1112-6MH32-0KA0

Siemens 3VA1 IEC frame 160, breaking capacity class H, 3-pole, 125A, 70kA @ 415V AC, starter protection TM120M, with shunt trip (STL) 220-250 V DC / 208-277 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA1112-6MH32-0KA0 is a 3-pole IEC frame 160 circuit breaker rated 125 A continuous, with a 70 kA breaking capacity at 415 V AC — that's class H on the 3VA1 platform, meaning it can safely interrupt fault currents up to that level without upstream cascading. The TM120M thermal-magnetic release provides starter protection (motor branch circuit), but note the description flags 'without overload protection' — the TM120M here is configured for short-circuit protection only, with an adjustable instantaneous trip Ii = 5–15 × In. The integrated shunt trip (STL) operates on 220–250 V DC or 208–277 V AC, letting you remotely trip the breaker from a safety circuit or E-stop chain.

Mounts on DIN rail in a standard IEC enclosure. The shunt trip occupies the accessory slot; verify coil voltage matches your control circuit before commissioning (220–250 V DC or 208–277 V AC). The 3VA1 frame 160 is physically compact for its 125 A rating, leaving fill-factor room in the gland plate for additional branch feeders.

Frequently asked questions

Where can I buy the 3VA1112-6MH32-0KA0?

This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

What does the 70 kA breaking capacity at 415 V mean for my application?

The 70 kA Icu at 415 V AC means this breaker can safely interrupt a fault current up to 70,000 amps without failing or cascading the fault upstream — class H on the 3VA1 frame. That's suitable for high-fault-capacity industrial panels where the available short-circuit current is substantial.

Does this breaker include overload protection?

No — the TM120M release on this variant is configured for short-circuit protection only (adjustable Ii = 5–15 × In). Overload protection is not provided, so you must size upstream or downstream overload relays separately for motor branch circuits.

MPN
3VA1112-6MH32-0KA0